98975725
Grundfos - NB 100-200/203AASF2AESBQQEUW1 End Suction Pump - 400V - Three Phase - 5400 Ltr/min. - Cast IronNB 100-200/203 AASF2AESBQQEUW1
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975798
Grundfos - NB 125-500/500AASF2AESBQQE1W3 End Suction Pump - 400V - Three Phase - 5374 Ltr/min. - Cast IronNB 125-500/500 AASF2AESBQQE1W3
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975886
Grundfos - NB 150-500/483AASF1AESBQQETW5 End Suction Pump - 400V - Three Phase - 5367 Ltr/min. - Cast IronNB 150-500/483 AASF1AESBQQETW5
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 10 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98606358
Grundfos - NK 100-200/203AA2F2AESBQQEUW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 5400 Ltr/min. - Cast IronNK 100-200/203 AA2F2AESBQQEUW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972389
Grundfos - NK 125-500/500AA2F2AESBQQE1W3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 5374 Ltr/min. - Cast IronNK 125-500/500 AA2F2AESBQQE1W3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972486
Grundfos - NK 150-500/483AA2F1AESBQQETW5 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 5337 Ltr/min. - Cast IronNK 150-500/483 AA2F1AESBQQETW5
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 10 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery