WIL-2121218
Wilo - Veroline IPL 65/115-1,5/2 IE3 Centrifugal Pump - 1.5 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2121201
Wilo - Veroline IPL 40/120-1.5/2 Centrifugal Pump - 1.50 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2089585
Wilo - Veroline IPL 40/115-0.55/2 -IE3 Centrifugal Pump - 0.55 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2152442
Wilo - Veroline IPL 50/95-0,55/2 Centrifugal Pump - 0.55 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2121194
Wilo - Veroline IPL 100/165-2,2/4 Centrifugal Pump - 2.20 kWThe Veroline IPL Centrifugal Pumps are a range of single-stage, low-pressure Centrifugal Pump in in line design with mechanical seal, flange connection with pressure measuring connection R 1/8 and motor with one-piece shaft.
Purchase from Pumpify and recieve free standard delivery.
Type key
Your advantagesExample
IPL 40/160-4/2
IPL
in line pump
40
Nominal diameter DN of the pipe connection
160
Nominal impeller diameter
4
Rated motor power P2 in kW
2
Number of poles
High standard of corrosion protection thanks to cataphoretic coating, Standard condensate drainage holes in the motor housings and lanterns, Series Product detail: motor with one-piece shaft, Version N: Standard motor V1 with Stainless Steel plug shaft, and Bidirectional, force-flushed mechanical seal.
Tech InfoPermissible temperature range -20 °C to +120 °C, Mains connection 3~400 V, 50 Hz (others on request), Protection class IP 55, Nominal diameter Rp 1 to DN 100, and Max. operating pressure 10 bar. (special version: 16 bar.).
Materials- Pump housing and lantern: EN-GJL-250
- Impeller: PPO fibreglass-reinforced EN-GJL-200 (depending on pump type)
- Shaft: 1.4021
- Mechanical seal: AQEGG; other mechanical seals on request
In stock
Free Standard Delivery
-
WIL-2121210
Wilo - Veroline IPL 50/130-2,2/2 Centrifugal Pump - 2.20 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2152934
Wilo - Veroline IPL 50/105-0,75/2 Centrifugal Pump - 0.75 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2121229
Wilo - Veroline IPL 80/105-3/2 Centrifugal Pump - 3.00 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
2158811
Wilo - VeroLine IP-E32/105-0,75/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mmGlanded Centrifugal Pump with in line design for pipe Installation manual with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v). Three-phase AC motor with frequency converter.
Product detail:
Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..
Accessories:
Mounting brackets for fixing to the foundation, IR-Monitor, IR-Stick, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, Control systems VR-HVAC/CCe-HVAC/SCe-HVAC, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.
Standard equipment:
- One-button manual operation level for:
- Pump On/Off
- Setpoint and speed adjustment
- Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
- Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
- Configuration of operating parameters
- Fault acknowledgement
- Pump display for displaying:
- Control mode
- Setpoint (e.g. differential pressure or speed)
- Error and warning messages
- Actual values (e.g. power consumption, actual value of the sensor)
- Operating data (e.g. operating hours, energy consumption)
- Status data (e.g. status of SSM and SBM relay)
- Device data (e.g. pump name)
Additional Product Functions:
- Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
- Adjustable time interval for pump cycling (in dual pump mode)
- Integrated full motor protection
- Different operating modes for heating mode (HV) or air-conditioning mode (AC)
- Access disable
- Different operation levels: Standard / Service
In stock
Free Standard Delivery
- One-button manual operation level for:
-
2158874
Wilo - VeroLine IP-E32/105-0,75/2-R1 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mmGlanded Centrifugal Pump with in line design for pipe Installation manual with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v). Three-phase AC motor with frequency converter.
Product detail:
Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..
Accessories:
Mounting brackets for fixing to the foundation, IR-Monitor, IR-Stick, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, Control systems VR-HVAC/CCe-HVAC/SCe-HVAC, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.
Standard equipment:
- One-button manual operation level for:
- Pump On/Off
- Setpoint and speed adjustment
- Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
- Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
- Configuration of operating parameters
- Fault acknowledgement
- Pump display for displaying:
- Control mode
- Setpoint (e.g. differential pressure or speed)
- Error and warning messages
- Actual values (e.g. power consumption, actual value of the sensor)
- Operating data (e.g. operating hours, energy consumption)
- Status data (e.g. status of SSM and SBM relay)
- Device data (e.g. pump name)
Additional Product Functions:
- Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
- Adjustable time interval for pump cycling (in dual pump mode)
- Integrated full motor protection
- Different operating modes for heating mode (HV) or air-conditioning mode (AC)
- Access disable
- Different operation levels: Standard / Service
In stock
Free Standard Delivery
- One-button manual operation level for:
-
2158812
Wilo - VeroLine IP-E32/125-1,1/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mmGlanded Centrifugal Pump with in line design for pipe Installation manual with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v). Three-phase AC motor with frequency converter.
Product detail:
Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..
Accessories:
Mounting brackets for fixing to the foundation, IR-Monitor, IR-Stick, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, Control systems VR-HVAC/CCe-HVAC/SCe-HVAC, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.
Standard equipment:
- One-button manual operation level for:
- Pump On/Off
- Setpoint and speed adjustment
- Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
- Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
- Configuration of operating parameters
- Fault acknowledgement
- Pump display for displaying:
- Control mode
- Setpoint (e.g. differential pressure or speed)
- Error and warning messages
- Actual values (e.g. power consumption, actual value of the sensor)
- Operating data (e.g. operating hours, energy consumption)
- Status data (e.g. status of SSM and SBM relay)
- Device data (e.g. pump name)
Additional Product Functions:
- Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
- Adjustable time interval for pump cycling (in dual pump mode)
- Integrated full motor protection
- Different operating modes for heating mode (HV) or air-conditioning mode (AC)
- Access disable
- Different operation levels: Standard / Service
In stock
Free Standard Delivery
- One-button manual operation level for:
-
2158875
Wilo - VeroLine IP-E32/125-1,1/2-R1 Centrifugal Pump - 38.v - Three Phase - 10 Bar. - 260mmGlanded Centrifugal Pump with in line design for pipe Installation manual with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v). Three-phase AC motor with frequency converter.
Product detail:
Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..
Accessories:
Mounting brackets for fixing to the foundation, IR-Monitor, IR-Stick, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, Control systems VR-HVAC/CCe-HVAC/SCe-HVAC, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.
Standard equipment:
- One-button manual operation level for:
- Pump On/Off
- Setpoint and speed adjustment
- Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
- Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
- Configuration of operating parameters
- Fault acknowledgement
- Pump display for displaying:
- Control mode
- Setpoint (e.g. differential pressure or speed)
- Error and warning messages
- Actual values (e.g. power consumption, actual value of the sensor)
- Operating data (e.g. operating hours, energy consumption)
- Status data (e.g. status of SSM and SBM relay)
- Device data (e.g. pump name)
Additional Product Functions:
- Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
- Adjustable time interval for pump cycling (in dual pump mode)
- Integrated full motor protection
- Different operating modes for heating mode (HV) or air-conditioning mode (AC)
- Access disable
- Different operation levels: Standard / Service
In stock
Free Standard Delivery
- One-button manual operation level for:
-
2158813
Wilo - VeroLine IP-E32/135-1,1/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mmGlanded Centrifugal Pump with in line design for pipe Installation manual with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v). Three-phase AC motor with frequency converter.
Product detail:
Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..
Accessories:
Mounting brackets for fixing to the foundation, IR-Monitor, IR-Stick, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, Control systems VR-HVAC/CCe-HVAC/SCe-HVAC, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.
Standard equipment:
- One-button manual operation level for:
- Pump On/Off
- Setpoint and speed adjustment
- Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
- Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
- Configuration of operating parameters
- Fault acknowledgement
- Pump display for displaying:
- Control mode
- Setpoint (e.g. differential pressure or speed)
- Error and warning messages
- Actual values (e.g. power consumption, actual value of the sensor)
- Operating data (e.g. operating hours, energy consumption)
- Status data (e.g. status of SSM and SBM relay)
- Device data (e.g. pump name)
Additional Product Functions:
- Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
- Adjustable time interval for pump cycling (in dual pump mode)
- Integrated full motor protection
- Different operating modes for heating mode (HV) or air-conditioning mode (AC)
- Access disable
- Different operation levels: Standard / Service
In stock
Free Standard Delivery
- One-button manual operation level for:
-
2158876
Wilo - VeroLine IP-E32/135-1,1/2-R1 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mmGlanded Centrifugal Pump with in line design for pipe Installation manual with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v). Three-phase AC motor with frequency converter.
Product detail:
Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..
Accessories:
Mounting brackets for fixing to the foundation, IR-Monitor, IR-Stick, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, Control systems VR-HVAC/CCe-HVAC/SCe-HVAC, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.
Standard equipment:
- One-button manual operation level for:
- Pump On/Off
- Setpoint and speed adjustment
- Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
- Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
- Configuration of operating parameters
- Fault acknowledgement
- Pump display for displaying:
- Control mode
- Setpoint (e.g. differential pressure or speed)
- Error and warning messages
- Actual values (e.g. power consumption, actual value of the sensor)
- Operating data (e.g. operating hours, energy consumption)
- Status data (e.g. status of SSM and SBM relay)
- Device data (e.g. pump name)
Additional Product Functions:
- Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
- Adjustable time interval for pump cycling (in dual pump mode)
- Integrated full motor protection
- Different operating modes for heating mode (HV) or air-conditioning mode (AC)
- Access disable
- Different operation levels: Standard / Service
In stock
Free Standard Delivery
- One-button manual operation level for:
-
2158814
Wilo - VeroLine IP-E32/135-1,5/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mmGlanded Centrifugal Pump with in line design for pipe Installation manual with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v). Three-phase AC motor with frequency converter.
Product detail:
Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..
Accessories:
Mounting brackets for fixing to the foundation, IR-Monitor, IR-Stick, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, Control systems VR-HVAC/CCe-HVAC/SCe-HVAC, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.
Standard equipment:
- One-button manual operation level for:
- Pump On/Off
- Setpoint and speed adjustment
- Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
- Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
- Configuration of operating parameters
- Fault acknowledgement
- Pump display for displaying:
- Control mode
- Setpoint (e.g. differential pressure or speed)
- Error and warning messages
- Actual values (e.g. power consumption, actual value of the sensor)
- Operating data (e.g. operating hours, energy consumption)
- Status data (e.g. status of SSM and SBM relay)
- Device data (e.g. pump name)
Additional Product Functions:
- Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
- Adjustable time interval for pump cycling (in dual pump mode)
- Integrated full motor protection
- Different operating modes for heating mode (HV) or air-conditioning mode (AC)
- Access disable
- Different operation levels: Standard / Service
In stock
Free Standard Delivery
- One-button manual operation level for:
-
2158877
Wilo - VeroLine IP-E32/135-1,5/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mmGlanded Centrifugal Pump with in line design for pipe Installation manual with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v). Three-phase AC motor with frequency converter.
Product detail:
Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..
Accessories:
Mounting brackets for fixing to the foundation, IR-Monitor, IR-Stick, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, Control systems VR-HVAC/CCe-HVAC/SCe-HVAC, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.
Standard equipment:
- One-button manual operation level for:
- Pump On/Off
- Setpoint and speed adjustment
- Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
- Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
- Configuration of operating parameters
- Fault acknowledgement
- Pump display for displaying:
- Control mode
- Setpoint (e.g. differential pressure or speed)
- Error and warning messages
- Actual values (e.g. power consumption, actual value of the sensor)
- Operating data (e.g. operating hours, energy consumption)
- Status data (e.g. status of SSM and SBM relay)
- Device data (e.g. pump name)
Additional Product Functions:
- Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
- Adjustable time interval for pump cycling (in dual pump mode)
- Integrated full motor protection
- Different operating modes for heating mode (HV) or air-conditioning mode (AC)
- Access disable
- Different operation levels: Standard / Service
In stock
Free Standard Delivery
- One-button manual operation level for:
Wilo VeroLine Pumps
The Wilo VeroLine is an in-line centrifugal pump built for heating, chilled water, and cooling systems. Designed for clean water and water/glycol mixtures, it keeps your system circulating without abrasive wear. With a durable mechanical seal, flanged connections, and corrosion-resistant coating, the VeroLine handles a wide temperature range and pressures up to 10 bar.