2164677
Wilo - Stratos Maxo-Z 65/0,5-12 PN6/10 Glandless Circulator Pump - 230V - Single Phase - 10 Bar. - 340mmPremium smart-pump Wilo-Stratos MAXO-Z
High-efficiency in-line glandless pump with EC motor and electronic power adjustment. can be utilised for drinking water, chilled water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between ⤠0.17 and ⤠0.19 depending on pump type.
Control modes:
In stock
Free Standard Delivery
-
99221237
Grundfos - MAGNA1 32-100F (220) Variable Speed Circulator Pump - 240V - Single Phase - 175 Ltr/min. - Cast IronMAGNA1 32-100 F
The Grundfos MAGNA1 circulator pump is the uncomplicated option for a job well done. With its high energy efficiency, the product complies with the EuP 2015 regulations, ensuring substantial savings on electricity. With its intuitive, user-friendly interface and maintenance-free design, MAGNA1 is the well-suited circulator pump for basic performance needs in applications where basic system control and monitoring are desired.
With this range of circulator pumps, everything from setup to basic control and monitoring are made straightforward. The pump is maintenance-free due to the canned-rotor type design. MAGNA1 offers the possibility of monitoring the pump via the fault relay output. The digital start and stop input remotely controls the pump. The pump communicates wirelessly with the Grundfos GO Remote app. MAGNA1 can work as the main pump in both heating and cooling applications, including:
- small chiller applications
- ground-source heat pump systems
- air-conditioning surfaces
- heating surfaces
- mixing loops
MAGNA1 is a single-phase pump characterised by the controller and operating panel being integrated in the control box. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled.
The pump incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Domestic heating, Industrial heating
In stock
Free Standard Delivery
-
98438148
Grundfos - TPE2 D 65-200 N-A-F-A-BQQE-IDC Commercial Circulator -400V - Three Phase - 581 Ltr/min. - Cast IronTPE2 D 65-200 N-A-F-A-BQQE-IWC
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
2217892
Wilo - Stratos Maxo 25/0,5-4 PN10-R7 Glandless Circulator Pump - 230V - Single Phase - 10 Bar. - 180mmPremium smart central heating pump Wilo-Stratos MAXO-R7
High efficiency in line glandless pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
- Thermal insulation shell for heating applications
Scope of delivery
- Pump
- Optimised Wilo-Connector the same for all sizes
- 2x threaded cable connection M16 x 1.5
- 2x gaskets
- Thermal insulation shell
- Concise Installation manual and operating instructions
Optional accessories:
- ClimaForm Cold insulation to avoid the formation of condensate
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217894
Wilo - Stratos Maxo 25/0,5-8 PN10-R7 Glandless Circulator Pump - 230V - Single Phase - 10 Bar. - 180mmPremium smart central heating pump Wilo-Stratos MAXO-R7
High efficiency in line glandless pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 0.17 and 0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
- Thermal insulation shell for heating applications
Scope of delivery
- Pump
- Optimised Wilo-Connector the same for all sizes
- 2x threaded cable connection M16 x 1.5
- 2x gaskets
- Thermal insulation shell
- Concise Installation manual and operating instructions
Optional accessories:
- ClimaForm Cold insulation to avoid the formation of condensate
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217895
Wilo - Stratos Maxo 25/0,5-10 PN10-R7 Glandless Circulator Pump - 230V - Single Phase - 10 Bar. - 180mmPremium smart-pump Wilo-Stratos MAXO-R7
High efficiency in line glandless pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 0.17 and 0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
- Thermal insulation shell for heating applications
Scope of delivery
- Pump
- Optimised Wilo-Connector the same for all sizes
- 2x threaded cable connection M16 x 1.5
- 2x gaskets
- Thermal insulation shell
- Concise Installation manual and operating instructions
Optional accessories:
- ClimaForm Cold insulation to avoid the formation of condensate
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217945
Wilo - Stratos maxo 32/0,5-8 R7 Glandless Circulator Pump - 230V - Single Phase - 10 Bar. - 220mmPremium smart central heating pump Wilo-Stratos MAXO-R7
High efficiency in line glandless pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
- Thermal insulation shell for heating applications
Scope of delivery
- Pump
- Optimised Wilo-Connector the same for all sizes
- 2x threaded cable connection M16 x 1.5
- 2x gaskets
- Thermal insulation shell
- Concise Installation manual and operating instructions
Optional accessories:
- ClimaForm Cold insulation to avoid the formation of condensate
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217904
Wilo - Stratos Maxo-D 30/0,5-10 PN10-R7 Twin Head Glandless Circulator Pump - 230V - Single Phase - 10 Bar. - 180mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217972
Wilo - Stratos Maxo 100/0,5-12 PN10-R7 Glandless Circulator Pump - 230V - Single Phase - 10 Bar. - 360mmPremium smart central heating pump Wilo-Stratos MAXO-R7
High efficiency in line glandless pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
- Thermal insulation shell for heating applications
Scope of delivery
- Pump
- Optimised Wilo-Connector the same for all sizes
- 2x threaded cable connection M16 x 1.5
- 2x gaskets
- Thermal insulation shell
- Concise Installation manual and operating instructions
Optional accessories:
- ClimaForm Cold insulation to avoid the formation of condensate
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
98437728
Grundfos - TPE2 100-120 N-A-F-A-BQQE-GAB Inline Single Stage Circulator Pump - 240V - Three Phase - Cast IronTPE2 100-120 N-A-F-A-BQQE-GWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
-
98437614
Grundfos - TPE2 100-120 N-A-F-A-BQQE-GDB Inline Single Stage Circulator Pump - 500v - Three Phase - Cast IronTPE2 100-120 N-A-F-A-BQQE-GWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
-
98437729
Grundfos - TPE2 100-150 N-A-F-A-BQQE-HAB Inline Single Stage Circulator Pump - 240V - Single Phase - Cast IronTPE2 100-150 N-A-F-A-BQQE-HWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
-
98437615
Grundfos - TPE2 100-150 N-A-F-A-BQQE-HDB Inline Single Stage Circulator Pump - 500v - Three Phase - Cast IronTPE2 100-150 N-A-F-A-BQQE-HWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
-
98437616
Grundfos - TPE2 100-180 N-A-F-A-BQQE-IDB Inline Single Stage Circulator Pump - 500v - Three Phase - Cast IronTPE2 100-180 N-A-F-A-BQQE-IWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
-
98437726
Grundfos - TPE2 100-40 N-A-F-A-BQQE-CAA Inline Single Stage Circulator Pump - 240V - Single Phase - Cast IronTPE2 100-40 N-A-F-A-BQQE-CYA
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
-
98437612
Grundfos - TPE2 100-40 N-A-F-A-BQQE-CDA Inline Single Stage Circulator Pump - 500v - Three Phase - Cast IronTPE2 100-40 N-A-F-A-BQQE-CYA
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
Circulating Pumps
Circulating pumps move slurries, liquids, and gases through a closed system, keeping heating, cooling, and hot water circuits flowing as they should. They are most commonly used in domestic and commercial heating systems to maintain a steady supply of hot water, but they also play a key role in underfloor heating, radiator circuits, and chilled water applications.
By keeping water moving continuously, circulating pumps help balance temperatures, reduce energy waste, and ensure that taps, showers, and heating systems respond instantly when needed. Hot water circulating pumps are particularly useful in larger properties or commercial setups, where waiting for water to heat can lead to unnecessary water and energy use.
At Pumpify, our range includes circulating pumps suitable for everything from simple domestic setups to more complex commercial systems. Designed for easy installation, straightforward maintenance, and long-term performance, these pumps ensure your heating and hot water systems operate smoothly, reliably, and cost-effectively.