-
GR-98958006
Grundfos - TPD 65-180/2 1.5kw 2900RPM BQQE Twin Head Pump - 415V - 1.5kWTPD 65-180/2 A-F-A-BQQE-HW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98958039
Grundfos - TPD 80-120/2 1.5kw 2900RPM BQQE Twin Head Pump - 415V - 1.5kWTPD 80-120/2 AI-F-A-BQQE-HW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98958094
Grundfos - TPD 100-120/2 BQQE 2.2kw 2900RPM Twin Head Pump - 415V - 2.2kWTPD 100-120/2 AI-F-A-BQQE-IW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98957945
Grundfos - TPD 32-30/4 0.12kw 1450RPM BQQE Twin Head Pump - 415V - 0.12kWTPD 32-30/4 A-F-A-BQQE-AW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98958184
Grundfos - TPD 32-40/4 0.18kw 1450RPM BQQE Twin Head Pump - 415V - 0.25kWTPD 32-40/4 A-F-A-BQQE-CW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98958180
Grundfos - TPD 32-60/4 0.18kw 1450RPM BQQE Twin Head Pump - 415V - 0.25kWTPD 32-60/4 A-F-A-BQQE-CW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98957955
Grundfos - TPD 40-30/4 0.12kw 1450RPM BQQE Twin Head Pump - 415V - 0.12kWTPD 40-30/4 A-F-A-BQQE-AW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98958181
Grundfos - TPD 40-90/4 0.18kw 1450RPM BQQE Twin Head Pump - 415V - 0.25kWTPD 40-90/4 A-F-A-BQQE-CW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98957969
Grundfos - TPD 50-30/4 0.18kw 1450RPM BQQE Twin Head Pump - 415V - 0.25kWTPD 50-30/4 A-F-A-BQQE-CW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98957990
Grundfos - TPD 65-30/4 0.25kw 1450RPM BQQE Twin Head Pump - 415V - 0.25kWTPD 65-30/4 A-F-A-BQQE-CW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98958017
Grundfos - TPD 80-30/4 0.37kw 1450RPM BQQE Twin Head Pump - 415VTPD 80-30/4 AI-F-A-BQQE-DW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98958031
Grundfos - TPD 80-60/4 0.75kw 1450RPM BQQE Twin Head Pump - 415V - 0.75kWTPD 80-60/4 AI-F-A-BQQE-FW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
GR-98958051
Grundfos - TPD 100-30/4 0.55kw 1450RPM BQQE Twin Head Pump - 415V - 0.55kWTPD 100-30/4 AI-F-A-BQQE-EW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
WIL-2089643
Wilo - VeroTwin DPL 40/115-0.55/2 - IE2 Centrifugal Pump - 0.55kWIn-line twin-head pump with two single-stage glanded centrifugal pumps in the same housing with switchover valve in the pressure port. Pump with compact in-line design with directly flanged three-phase current motor and one-piece shafts or with lanterns and standard motors (version N) rigidly connected by couplings.
The DPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seals and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2121253
Wilo - VeroTwin DPL 50/130-2,2/2 Centrifugal Pump - 2.20kWIn-line twin-head pump with two single-stage glanded centrifugal pumps in the same housing with switchover valve in the pressure port. Pump with compact in-line design with directly flanged three-phase current motor and one-piece shafts or with lanterns and standard motors (version N) rigidly connected by couplings.
The DPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seals and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2121272
Wilo - VeroTwin DPL 80/105-3/2 Centrifugal Pump - 3.00kWIn-line twin-head pump with two single-stage glanded centrifugal pumps in the same housing with switchover valve in the pressure port. Pump with compact in-line design with directly flanged three-phase current motor and one-piece shafts or with lanterns and standard motors (version N) rigidly connected by couplings.
The DPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seals and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
Circulating Pumps
Circulating pumps move slurries, liquids, and gases through a closed system, keeping heating, cooling, and hot water circuits flowing as they should. They are most commonly used in domestic and commercial heating systems to maintain a steady supply of hot water, but they also play a key role in underfloor heating, radiator circuits, and chilled water applications.
By keeping water moving continuously, circulating pumps help balance temperatures, reduce energy waste, and ensure that taps, showers, and heating systems respond instantly when needed. Hot water circulating pumps are particularly useful in larger properties or commercial setups, where waiting for water to heat can lead to unnecessary water and energy use.
At Pumpify, our range includes circulating pumps suitable for everything from simple domestic setups to more complex commercial systems. Designed for easy installation, straightforward maintenance, and long-term performance, these pumps ensure your heating and hot water systems operate smoothly, reliably, and cost-effectively.















