99272191
Grundfos - TPE3 80-180 S-A-F-A-BQQE-IDB Inline Single Stage Circulator Pump - 500v - Three Phase - Cast IronTPE3 80-180 S-A-F-A-BQQE-IWB
Single-stage, close-coupled, volute Pump with in-line suction and discharge ports of identical diameter. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. The shaft seal is according to EN 12756. Pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). The Pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The Pump is equipped with a fan-cooled asynchronous motor. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272196
Grundfos - TPE3 80-40 S-A-F-A-BQQE-CAA Inline Single Stage Circulator Pump - 240V - Single Phase - Cast IronTPE3 80-40 S-A-F-A-BQQE-CYA
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
99272188
Grundfos - TPE3 80-40 S-A-F-A-BQQE-CDA Inline Single Stage Circulator Pump - 500v - Three Phase - Cast IronTPE3 80-40 S-A-F-A-BQQE-CYA
Single-stage, close-coupled, volute Pump with in-line suction and discharge ports of identical diameter. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. The shaft seal is according to EN 12756. Pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). The Pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The Pump is equipped with a fan-cooled asynchronous motor. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272538
Grundfos - TPE3 D 100-120 S-A-F-A-BQQE-GAB Inline Twin Head Circulator Pump - 240V - Single Phase - Cast IronTPE3 D 100-120 S-A-F-A-BQQE-GWB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
99272531
Grundfos - TPE3 D 100-120 S-A-F-A-BQQE-GDB Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 100-120 S-A-F-A-BQQE-GWB
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272539
Grundfos - TPE3 D 100-150 S-A-F-A-BQQE-HAB Inline Twin Head Circulator Pump - 240V - Single PhaseGrundfos TPED Series 2000, TPE3 D pumps are single-stage, close-coupled in-line centrifugal twin-head pumps with mechanical shaft seal and primely for applications such as heating/cooling/ district energy. The pumps are fitted with frequency controlled motors and differential pressure transmitter.
2 week lead time
Free Standard Delivery
-
99272532
Grundfos - TPE3 D 100-150 S-A-F-A-BQQE-HDB Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 100-150 S-A-F-A-BQQE-HWB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
99272533
Grundfos - TPE3 D 100-180 S-A-F-A-BQQE-IDB Inline Twin Head Circulator Pump - 500v - Three PhaseGrundfos TPED Series 2000, TPE3 D pumps are single-stage, close-coupled in-line centrifugal twin-head pumps with mechanical shaft seal and primely for applications such as heating/cooling/ district energy. The pumps are fitted with frequency controlled motors and differential pressure transmitter.
2 week lead time
Free Standard Delivery
-
99272537
Grundfos - TPE3 D 100-40 S-A-F-A-BQQE-CAA Inline Twin Head Circulator Pump - 240V - Single Phase - Cast IronTPE3 D 100-40 S-A-F-A-BQQE-CYA
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272530
Grundfos - TPE3 D 100-40 S-A-F-A-BQQE-CDA Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 100-40 S-A-F-A-BQQE-CYA
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272560
Grundfos - TPE3 D 65-120 S-A-F-A-BQQE-FDB Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 65-120 S-A-F-A-BQQE-FWB
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272602
Grundfos - TPE3 D 65-150 S-A-F-A-BQQE-GAB Inline Twin Head Circulator Pump - 240V - Single Phase - Cast IronTPE3 D 65-150 S-A-F-A-BQQE-GWB
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272561
Grundfos - TPE3 D 65-150 S-A-F-A-BQQE-GDB Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 65-150 S-A-F-A-BQQE-GWB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
99272603
Grundfos - TPE3 D 65-180 S-A-F-A-BQQE-HAC Inline Twin Head Circulator Pump - 240V - Single Phase - Cast IronTPE3 D 65-180 S-A-F-A-BQQE-HWC
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supplyView moreDistrict cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272562
Grundfos - TPE3 D 65-180 S-A-F-A-BQQE-HDC Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 65-180 S-A-F-A-BQQE-HWC
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272573
Grundfos - TPE3 D 65-200 S-A-F-A-BQQE-IDC Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 65-200 S-A-F-A-BQQE-IWC
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
Heating Circulators
Heating circulator pumps keep hot water moving through radiators, baseboards, and underfloor heating systems. They ensure your heating system delivers warmth quickly, reduces waiting times for hot water, and keeps energy use under control.
Whether used individually or in combination, circulator pumps can serve multiple zones, giving precise control over each area of your property. In multi-zone systems, one circulator can serve all areas using control valves for each section, or you can fit a dedicated pump to each zone for precise, independent flow.
Modern circulators save significant power while maintaining consistent flow. Pumpify offers a range of trusted models from big name brands that are built for durability, smooth operation, and long-lasting performance, helping you get the most out of your heating system.