2046673
Wilo - TOP-S 50/10 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046674
Wilo - TOP-S 50/15 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046675/29991433
Wilo - TOP-S 65/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046676 / 29991437
Wilo - TOP-S 65/10 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046694 / 29991435
Wilo - TOP-S 65/10 REPLACEMENT Head - 230V - Single PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2048321/29991402
Wilo - TOP-S 25/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2048334/29991401
Wilo - TOP-S 25/7 REPLACEMENT Head - 230V - Single PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2048336/29991408
Wilo - TOP-S 30/7 REPLACEMENT Head - 230V - Single PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2080017
Wilo - TOP-S 40/10 REPLACEMENT Head - 230V - Single PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2080018
Wilo - TOP-S 50/7 REPLACEMENT Head - 230V - 1 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
29991405
Wilo - TOP-S 30/5 REPLACEMENT Head - 230V - Single PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Replacement Motor and Terminal Box to repair a Wilo - TOP-S/SD 30/5
In stock
Free Standard Delivery
-
GR-98707851
Grundfos - UPS2 32-80 Heating Circulator Pump - 240V - 180mm - Cast IronUPS2 32-80 180
High-efficiency circulator pump unit with permanent-magnet motor (ECM technology) fit for the ErP directive no. 641/2009 due to continuous variable-speed control for circulation of clean heating water according to VDI 2035.
Features and benefits: UPS2 32-80 180
High-efficiency circulator pump with permanent-magnet motor (ECM technology) complying with the ErP directive no. 641/2009 thanks to continuous variable-speed control. appropriate for circulation of clean heating water according to VDI 2035.
Features and benefits:
- reduced installation costs as no external motor protection is required
- no corrosion issues thanks to the electrocoated pump housing
- one button for uncomplicated selection among three proportional-pressure curves or three fixed speeds
- complies with the German regulation on energy saving in buildings and building systems – Energieeinsparverordnung – EnEV §14(3)
- high energy savings thanks to an energy efficiency index (EEI) lower than 0.23
- for tight installations, in, for example, boiler applications
- it is available as pump head without pump housing. Fits all 4-m, 5-m and 6-m pump housings of the Series 100
- one pump replaces three variants
- complies with the requirements of the ErP directive as from 2015
Suitable for: Commercial heating
In stock
Free Standard Delivery
-
99221239
Grundfos - Magna1 D32-60 Twin Variable Speed Circulator - 180mm - 230V - Cast IronMAGNA1 D 32-60
The Grundfos MAGNA1 D circulator pump is the uncomplicated option for a job well done. With its high energy efficiency, the product complies with the EuP 2015 regulations, ensuring substantial savings on electricity. With its intuitive, user-friendly interface and maintenance-free design, MAGNA1 D is the well-suited circulator pump for basic performance needs in applications where basic system control and monitoring are desired.
With this range of circulator pumps, everything from setup to basic control and monitoring are made straightforward. The pump is maintenance-free due to the canned-rotor type design. MAGNA1 D offers peace of mind due to the security of supply obtained by having a redundant pump, resulting in improved uptime. The flow, and thereby constant comfort, is secured because of its ability to automatically switch between pump heads if one breaks down. The two pumps communicate wirelessly. MAGNA1 D offers the possibility of monitoring the pump via the fault relay output. The digital start and stop input remotely controls the pump. The pump communicates wirelessly with the Grundfos GO Remote app and can also communicate via radio. MAGNA1 D can work as the main pump in both heating and cooling applications, including:
- small chiller applications
- ground-source heat pump systems
- air-conditioning surfaces
- heating surfaces
- mixing loops
MAGNA1 D is a single-phase pump characterised by the controller and operating panel being integrated in the control box. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled.
The pump incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Domestic heating, Industrial heating
In stock
Free Standard Delivery
-
99221374
Grundfos - Magna1 65-120F 99221374 Variable Speed Circulator - 340mm - 230V - Cast IronMAGNA1 65-120 F
The Grundfos MAGNA1 circulator pump is the uncomplicated option for a job to run reliably. With its high energy efficiency, the product complies with the EuP 2015 regulations, ensuring substantial savings on electricity. With its intuitive, user-friendly interface and maintenance-free design, MAGNA1 is the well-suited circulator pump for basic performance needs in applications where basic system control and monitoring are desired.
Grundfos Magna1 65-120F (340) ERP/EUP ready variable-speed Circulator Pump.
The Grundfos Magna1 65-120F (340) is a variable-speed circulator which is used primarily for one and two-pipe heating systems.
The Grundfos Magna1 range are energy efficient variable-speed circulators which comply with ERP/EUP European legislation.
NOTE: THIS PUMP HAS FLANGED CONNECTIONS.
With this range of circulator pumps, everything from setup to basic control and monitoring are made straightforward. The pump is maintenance-free due to the canned-rotor type design. MAGNA1 offers the possibility of monitoring the pump via the fault relay output. The digital start and stop input remotely controls the pump. The pump communicates wirelessly with the Grundfos GO Remote app. MAGNA1 can work as the main pump in both heating and cooling applications, including:
- small chiller applications
- ground-source heat pump systems
- air-conditioning surfaces
- heating surfaces
- mixing loops
MAGNA1 is a single-phase pump characterised by the controller and operating panel being integrated in the control box. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled.
The pump incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Domestic heating, Industrial heating
In stock
Free Standard Delivery
-
99221339
Grundfos - Magna1 D50-60F 99221339 Twin Variable Speed Circulator - 240mm - 230V - Cast IronMAGNA1 D 50-60 F
The Grundfos MAGNA1 D circulator pump is the uncomplicated option for a job well done. With its high energy efficiency, the product complies with the EuP 2015 regulations, ensuring substantial savings on electricity. With its intuitive, user-friendly interface and maintenance-free design, MAGNA1 D is the well-suited circulator pump for basic performance needs in applications where basic system control and monitoring are desired.
With this range of circulator pumps, everything from setup to basic control and monitoring are made straightforward. The pump is maintenance-free due to the canned-rotor type design. MAGNA1 D offers peace of mind due to the security of supply obtained by having a redundant pump, resulting in improved uptime. The flow, and thereby constant comfort, is secured because of its ability to automatically switch between pump heads if one breaks down. The two pumps communicate wirelessly. MAGNA1 D offers the possibility of monitoring the pump via the fault relay output. The digital start and stop input remotely controls the pump. The pump communicates wirelessly with the Grundfos GO Remote app and can also communicate via radio. MAGNA1 D can work as the main pump in both heating and cooling applications, including:
- small chiller applications
- ground-source heat pump systems
- air-conditioning surfaces
- heating surfaces
- mixing loops
MAGNA1 D is a single-phase pump characterised by the controller and operating panel being integrated in the control box. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled.
The pump incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Domestic heating, Industrial heating
In stock
Free Standard Delivery
-
99221376
Grundfos - Magna1 D65-40F 99221376 Twin Variable Speed Circulator - 340mm - 230V - Cast IronMAGNA1 D 65-40 F
The Grundfos MAGNA1 D circulator pump is the uncomplicated option for a job well done. With its high energy efficiency, the product complies with the EuP 2015 regulations, ensuring substantial savings on electricity. With its intuitive, user-friendly interface and maintenance-free design, MAGNA1 D is the well-suited circulator pump for basic performance needs in applications where basic system control and monitoring are desired.
With this range of circulator pumps, everything from setup to basic control and monitoring are made straightforward. The pump is maintenance-free due to the canned-rotor type design. MAGNA1 D offers peace of mind due to the security of supply obtained by having a redundant pump, resulting in improved uptime. The flow, and thereby constant comfort, is secured because of its ability to automatically switch between pump heads if one breaks down. The two pumps communicate wirelessly. MAGNA1 D offers the possibility of monitoring the pump via the fault relay output. The digital start and stop input remotely controls the pump. The pump communicates wirelessly with the Grundfos GO Remote app and can also communicate via radio. MAGNA1 D can work as the main pump in both heating and cooling applications, including:
- small chiller applications
- ground-source heat pump systems
- air-conditioning surfaces
- heating surfaces
- mixing loops
MAGNA1 D is a single-phase pump characterised by the controller and operating panel being integrated in the control box. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled.
The pump incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Domestic heating, Industrial heating
In stock
Free Standard Delivery
Heating Circulators
Heating circulator pumps keep hot water moving through radiators, baseboards, and underfloor heating systems. They ensure your heating system delivers warmth quickly, reduces waiting times for hot water, and keeps energy use under control.
Whether used individually or in combination, circulator pumps can serve multiple zones, giving precise control over each area of your property. In multi-zone systems, one circulator can serve all areas using control valves for each section, or you can fit a dedicated pump to each zone for precise, independent flow.
Modern circulators save significant power while maintaining consistent flow. Pumpify offers a range of trusted models from big name brands that are built for durability, smooth operation, and long-lasting performance, helping you get the most out of your heating system.