Heating Circulators

(1635 products)

Optionally, use our Pump Finder to find the Heating Circulators best suited to you:
Use our Pump Finder to find the right pump for you
Electrical supply:
AC Power:
Flow Rate:
More Options
1 products in this section | View All
Filters Products
View as Grid List

192 Items

per page
Filter Products
Set Descending Direction
  1. Wilo TOP-S 50/10 Replacement Head - 3 Phase

    2046673

    Wilo - TOP-S 50/10 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £1,863.60 RRP £1,211.34 £1,009.45
    In Stock In stock
    Delivery Icon Free Standard Delivery
  2. Wilo TOP-S 50/15 Replacement Head - 3 Phase

    2046674

    Wilo - TOP-S 50/15 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £2,589.60 RRP £1,683.24 £1,402.70
    In Stock In stock
    Delivery Icon Free Standard Delivery
  3. Wilo TOP-S 65/7 Replacement Head - 3 Phase

    2046675/29991433

    Wilo - TOP-S 65/7 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £1,807.20 RRP £1,174.68 £978.90
    In Stock In stock
    Delivery Icon Free Standard Delivery
  4. Wilo TOP-S 65/10 Replacement Head - 3 Phase

    2046676 / 29991437

    Wilo - TOP-S 65/10 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £2,230.80 RRP £1,450.02 £1,208.35
    In Stock In stock
    Delivery Icon Free Standard Delivery
  5. Wilo TOP-S 65/10 Replacement Head - Single Phase

    2046694 / 29991435

    Wilo - TOP-S 65/10 REPLACEMENT Head - 230V - Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £2,007.60 RRP £1,304.94 £1,087.45
    In Stock In stock
    Delivery Icon Free Standard Delivery
  6. Wilo TOP-S 25/7 Replacement Head - 3 Phase

    2048321/29991402

    Wilo - TOP-S 25/7 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £650.40 RRP £422.76 £352.30
    In Stock In stock
    Delivery Icon Free Standard Delivery
  7. Wilo TOP-S 25/7 Replacement Head - Single Phase

    2048334/29991401

    Wilo - TOP-S 25/7 REPLACEMENT Head - 230V - Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £585.60 RRP £380.64 £317.20
    In Stock In stock
    Delivery Icon Free Standard Delivery
  8. Wilo TOP-S 30/7 Replacement Head - Single Phase

    2048336/29991408

    Wilo - TOP-S 30/7 REPLACEMENT Head - 230V - Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £648.00 RRP £421.20 £351.00
    In Stock In stock
    Delivery Icon Free Standard Delivery
  9. Wilo TOP-S 40/10 Replacement Head - Single Phase

    2080017

    Wilo - TOP-S 40/10 REPLACEMENT Head - 230V - Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £1,383.60 RRP £899.34 £749.45
    In Stock In stock
    Delivery Icon Free Standard Delivery
  10. Wilo TOP-S 50/7 Replacement Head - 1 Phase

    2080018

    Wilo - TOP-S 50/7 REPLACEMENT Head - 230V - 1 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £1,668.00 RRP £1,084.20 £903.50
    In Stock In stock
    Delivery Icon Free Standard Delivery
  11. Wilo TOP-S 30/5 Replacement Head - Single Phase

    29991405

    Wilo - TOP-S 30/5 REPLACEMENT Head - 230V - Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Replacement Motor and Terminal Box to repair a Wilo - TOP-S/SD 30/5

    £571.20 RRP £371.28 £309.40
    In Stock In stock
    Delivery Icon Free Standard Delivery
  12. Grundfos UPS2 32-80 Heating Circulator Pump - 240v - 180mm

    GR-98707851

    Grundfos - UPS2 32-80 Heating Circulator Pump - 240V - 180mm - Cast Iron

    UPS2 32-80 180

    High-efficiency circulator pump unit with permanent-magnet motor (ECM technology) fit for the ErP directive no. 641/2009 due to continuous variable-speed control for circulation of clean heating water according to VDI 2035.

    Features and benefits: UPS2 32-80 180

    High-efficiency circulator pump with permanent-magnet motor (ECM technology) complying with the ErP directive no. 641/2009 thanks to continuous variable-speed control. appropriate for circulation of clean heating water according to VDI 2035.

    Features and benefits:

    • reduced installation costs as no external motor protection is required
    • no corrosion issues thanks to the electrocoated pump housing
    • one button for uncomplicated selection among three proportional-pressure curves or three fixed speeds
    • complies with the German regulation on energy saving in buildings and building systems – Energieeinsparverordnung – EnEV §14(3)
    • high energy savings thanks to an energy efficiency index (EEI) lower than 0.23
    • for tight installations, in, for example, boiler applications
    • it is available as pump head without pump housing. Fits all 4-m, 5-m and 6-m pump housings of the Series 100
    • one pump replaces three variants
    • complies with the requirements of the ErP directive as from 2015

    Suitable for: Commercial heating


    £763.20 RRP £414.00 £345.00
    In Stock In stock
    Delivery Icon Free Standard Delivery
  13. Grundfos Magna1 D32-60 Twin Variable Speed Circulator - 180mm - 230v

    99221239

    Grundfos - Magna1 D32-60 Twin Variable Speed Circulator - 180mm - 230V - Cast Iron

    MAGNA1 D 32-60

    The Grundfos MAGNA1 D circulator pump is the uncomplicated option for a job well done. With its high energy efficiency, the product complies with the EuP 2015 regulations, ensuring substantial savings on electricity. With its intuitive, user-friendly interface and maintenance-free design, MAGNA1 D is the well-suited circulator pump for basic performance needs in applications where basic system control and monitoring are desired.

    With this range of circulator pumps, everything from setup to basic control and monitoring are made straightforward. The pump is maintenance-free due to the canned-rotor type design. MAGNA1 D offers peace of mind due to the security of supply obtained by having a redundant pump, resulting in improved uptime. The flow, and thereby constant comfort, is secured because of its ability to automatically switch between pump heads if one breaks down. The two pumps communicate wirelessly. MAGNA1 D offers the possibility of monitoring the pump via the fault relay output. The digital start and stop input remotely controls the pump. The pump communicates wirelessly with the Grundfos GO Remote app and can also communicate via radio. MAGNA1 D can work as the main pump in both heating and cooling applications, including:

    • small chiller applications
    • ground-source heat pump systems
    • air-conditioning surfaces
    • heating surfaces
    • mixing loops

    MAGNA1 D is a single-phase pump characterised by the controller and operating panel being integrated in the control box. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled.

    The pump incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.

    Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Domestic heating, Industrial heating


    £2,295.60 RRP £1,331.45 £1,109.54
    In Stock In stock
    Delivery Icon Free Standard Delivery
  14. Grundfos Magna1 65-120F 99221374 Variable Speed Circulator - 340mm - 230v

    99221374

    Grundfos - Magna1 65-120F 99221374 Variable Speed Circulator - 340mm - 230V - Cast Iron

    MAGNA1 65-120 F

    The Grundfos MAGNA1 circulator pump is the uncomplicated option for a job to run reliably. With its high energy efficiency, the product complies with the EuP 2015 regulations, ensuring substantial savings on electricity. With its intuitive, user-friendly interface and maintenance-free design, MAGNA1 is the well-suited circulator pump for basic performance needs in applications where basic system control and monitoring are desired.

    Grundfos Magna1 65-120F (340) ERP/EUP ready variable-speed Circulator Pump.

    The Grundfos Magna1 65-120F (340) is a variable-speed circulator which is used primarily for one and two-pipe heating systems.

    The Grundfos Magna1 range are energy efficient variable-speed circulators which comply with ERP/EUP European legislation.

    NOTE: THIS PUMP HAS FLANGED CONNECTIONS.

    With this range of circulator pumps, everything from setup to basic control and monitoring are made straightforward. The pump is maintenance-free due to the canned-rotor type design. MAGNA1 offers the possibility of monitoring the pump via the fault relay output. The digital start and stop input remotely controls the pump. The pump communicates wirelessly with the Grundfos GO Remote app. MAGNA1 can work as the main pump in both heating and cooling applications, including:

    • small chiller applications
    • ground-source heat pump systems
    • air-conditioning surfaces
    • heating surfaces
    • mixing loops

    MAGNA1 is a single-phase pump characterised by the controller and operating panel being integrated in the control box. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled.

    The pump incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.

    Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Domestic heating, Industrial heating


    £4,080.00 RRP £2,366.40 £1,972.00
    In Stock In stock
    Delivery Icon Free Standard Delivery
  15. Grundfos Magna1 D50-60F 99221339 Twin Variable Speed Circulator - 240mm - 230v

    99221339

    Grundfos - Magna1 D50-60F 99221339 Twin Variable Speed Circulator - 240mm - 230V - Cast Iron

    MAGNA1 D 50-60 F

    The Grundfos MAGNA1 D circulator pump is the uncomplicated option for a job well done. With its high energy efficiency, the product complies with the EuP 2015 regulations, ensuring substantial savings on electricity. With its intuitive, user-friendly interface and maintenance-free design, MAGNA1 D is the well-suited circulator pump for basic performance needs in applications where basic system control and monitoring are desired.

    With this range of circulator pumps, everything from setup to basic control and monitoring are made straightforward. The pump is maintenance-free due to the canned-rotor type design. MAGNA1 D offers peace of mind due to the security of supply obtained by having a redundant pump, resulting in improved uptime. The flow, and thereby constant comfort, is secured because of its ability to automatically switch between pump heads if one breaks down. The two pumps communicate wirelessly. MAGNA1 D offers the possibility of monitoring the pump via the fault relay output. The digital start and stop input remotely controls the pump. The pump communicates wirelessly with the Grundfos GO Remote app and can also communicate via radio. MAGNA1 D can work as the main pump in both heating and cooling applications, including:

    • small chiller applications
    • ground-source heat pump systems
    • air-conditioning surfaces
    • heating surfaces
    • mixing loops

    MAGNA1 D is a single-phase pump characterised by the controller and operating panel being integrated in the control box. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled.

    The pump incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.

    Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Domestic heating, Industrial heating


    £5,521.20 RRP £3,202.30 £2,668.58
    In Stock In stock
    Delivery Icon Free Standard Delivery
  16. Grundfos Magna1 D65-40F 99221376 Twin Variable Speed Circulator - 340mm - 230v

    99221376

    Grundfos - Magna1 D65-40F 99221376 Twin Variable Speed Circulator - 340mm - 230V - Cast Iron

    MAGNA1 D 65-40 F

    The Grundfos MAGNA1 D circulator pump is the uncomplicated option for a job well done. With its high energy efficiency, the product complies with the EuP 2015 regulations, ensuring substantial savings on electricity. With its intuitive, user-friendly interface and maintenance-free design, MAGNA1 D is the well-suited circulator pump for basic performance needs in applications where basic system control and monitoring are desired.

    With this range of circulator pumps, everything from setup to basic control and monitoring are made straightforward. The pump is maintenance-free due to the canned-rotor type design. MAGNA1 D offers peace of mind due to the security of supply obtained by having a redundant pump, resulting in improved uptime. The flow, and thereby constant comfort, is secured because of its ability to automatically switch between pump heads if one breaks down. The two pumps communicate wirelessly. MAGNA1 D offers the possibility of monitoring the pump via the fault relay output. The digital start and stop input remotely controls the pump. The pump communicates wirelessly with the Grundfos GO Remote app and can also communicate via radio. MAGNA1 D can work as the main pump in both heating and cooling applications, including:

    • small chiller applications
    • ground-source heat pump systems
    • air-conditioning surfaces
    • heating surfaces
    • mixing loops

    MAGNA1 D is a single-phase pump characterised by the controller and operating panel being integrated in the control box. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled.

    The pump incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.

    Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Domestic heating, Industrial heating


    £5,878.80 RRP £3,409.70 £2,841.42
    In Stock In stock
    Delivery Icon Free Standard Delivery
View as Grid List

192 Items

per page
Filter Products
Set Descending Direction
Heating Circulators

Heating Circulators

Heating circulator pumps keep hot water moving through radiators, baseboards, and underfloor heating systems. They ensure your heating system delivers warmth quickly, reduces waiting times for hot water, and keeps energy use under control.

 

Whether used individually or in combination, circulator pumps can serve multiple zones, giving precise control over each area of your property. In multi-zone systems, one circulator can serve all areas using control valves for each section, or you can fit a dedicated pump to each zone for precise, independent flow.

 

Modern circulators save significant power while maintaining consistent flow. Pumpify offers a range of trusted models from big name brands that are built for durability, smooth operation, and long-lasting performance, helping you get the most out of your heating system.