Heating Circulators

(1635 products)

Optionally, use our Pump Finder to find the Heating Circulators best suited to you:
Use our Pump Finder to find the right pump for you
Electrical supply:
AC Power:
Flow Rate:
More Options
2 products in this section | View All
Filters Products
View as Grid List

86 Items

Page
per page
Filter Products
Set Descending Direction
  1. Grundfos UPS 15-50N Domestic Hot Water Service Pump Circulator - 230v

    GR-97549426

    Grundfos - UPS 15-50N Domestic Hot Water Service Pump Circulator - 230V - Stainless Steel

    UPS 15-50 N 130
    The pump unit is of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricatd by the pumped liquid. The pump has 3-step speed selector. The pump is characterized by:

    • Stainless Steel pump housing
    • corrosion-protected impeller, Composite
    • Stainless Steel rotor can and bearing plate
    • Carbon axial bearing
    • Ceramic shaft and radial bearings

    The motor is a 1-phase motor. No additional motor protection is required.

    Suitable for: Commercial heating, Domestic heating, Domestic hot water recirculation


    £565.20 RRP £346.82 £289.02
    In Stock In stock
    Delivery Icon Free Standard Delivery
  2. Grundfos Magna3 50-120F 97924284 Variable Speed Circulator

    Gr-97924284

    Grundfos - Magna3 50-120F 97924284 Variable Speed Circulator - 230V - Stainless Steel

    MAGNA3 50-120 F

    The Grundfos MAGNA3 circulator pump is the well-suited choice for almost any building project – old or new. With its unrivalled energy efficiency, all-encompassing range and built-in communication capabilities, MAGNA3 is well-suited for engineers and specifiers looking to create high-performance heating and cooling systems. The pump is maintenance-free due to the canned-rotor type design. This also means that pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. MAGNA3 features an intuitive display and allows you to connect wirelessly with the Grundfos GO Remote app, giving you access to enhanced reporting and monitoring. MAGNA3 model E has Bluetooth, which allows you to connect directly to the Grundfos GO app on your smart phone without any need for a dongle. The pump includes fieldbus communication via CIM modules as well as analogue and digital inputs and configurable relays. Control features include AUTOADAPT and FLOWADAPT. FLOWADAPT reduces the need for throttling valves, thus cutting costs on system components. MAGNA3 is the superior choice for a wide range of heating and cooling applications, including:

    • small chiller applications
    • ground-source heat pump systems
    • air conditioning surfaces
    • heating surfaces
    • mixing loops
    MAGNA3 is a single-phase pump characterised by the controller and control display being integrated in the control box. The pump also has a built-in differential pressure and temperature sensor. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled. MAGNA3 incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.

    Suitable for: Commercial heating


    £4,574.40 RRP £2,653.15 £2,210.96
    In Stock In stock
    Delivery Icon Free Standard Delivery
  3. Grundfos TP 32-180/2 0.55kw 2900RPM Commercial Circulator Pump

    GR-98958116

    Grundfos - TP 32-180/2 0.55kw 2900RPM Commercial Circulator Pump - Single Head - 230V - 0.55kW

    TP 32-180/2 A-F-A-BQQE-EW1

    Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled asynchronous motor.

    Suitable for: Commercial air conditioning


    £2,288.40 RRP £1,487.46 £1,239.55
    In Stock In stock
    Delivery Icon Free Standard Delivery
  4. Wilo TOP-S 30/10 Replacement Head - Single Phase

    2046663

    Wilo - TOP-S 30/10 REPLACEMENT Head - 230V -Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £898.80 RRP £584.22 £486.85
    In Stock In stock
    Delivery Icon Free Standard Delivery
  5. Wilo TOP-S 40/7 Replacement Head - Single Phase

    2046665

    Wilo - TOP-S 40/7 REPLACEMENT Head - 230V - Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £1,084.80 RRP £705.12 £587.60
    In Stock In stock
    Delivery Icon Free Standard Delivery
  6. Wilo TOP-S 40/7 Replacement Head - 3 Phase

    2046666

    Wilo - TOP-S 40/7 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £1,084.80 RRP £705.12 £587.60
    In Stock In stock
    Delivery Icon Free Standard Delivery
  7. Wilo TOP-S 50/4 Replacement Head - Single Phase

    2046668

    Wilo - TOP-S 50/4 REPLACEMENT Head - 230V - Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £1,467.60 RRP £953.94 £794.95
    In Stock In stock
    Delivery Icon Free Standard Delivery
  8. Wilo TOP-S 50/7 Replacement Head - 3 Phase

    2046672

    Wilo - TOP-S 50/7 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £1,852.80 RRP £1,204.32 £1,003.60
    In Stock In stock
    Delivery Icon Free Standard Delivery
  9. Wilo TOP-S 50/10 Replacement Head - 3 Phase

    2046673

    Wilo - TOP-S 50/10 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £1,863.60 RRP £1,211.34 £1,009.45
    In Stock In stock
    Delivery Icon Free Standard Delivery
  10. Wilo TOP-S 50/15 Replacement Head - 3 Phase

    2046674

    Wilo - TOP-S 50/15 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £2,589.60 RRP £1,683.24 £1,402.70
    In Stock In stock
    Delivery Icon Free Standard Delivery
  11. Wilo TOP-S 65/7 Replacement Head - 3 Phase

    2046675/29991433

    Wilo - TOP-S 65/7 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £1,807.20 RRP £1,174.68 £978.90
    In Stock In stock
    Delivery Icon Free Standard Delivery
  12. Wilo TOP-S 65/10 Replacement Head - 3 Phase

    2046676 / 29991437

    Wilo - TOP-S 65/10 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £2,230.80 RRP £1,450.02 £1,208.35
    In Stock In stock
    Delivery Icon Free Standard Delivery
  13. Wilo TOP-S 65/10 Replacement Head - Single Phase

    2046694 / 29991435

    Wilo - TOP-S 65/10 REPLACEMENT Head - 230V - Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £2,007.60 RRP £1,304.94 £1,087.45
    In Stock In stock
    Delivery Icon Free Standard Delivery
  14. Wilo TOP-S 25/7 Replacement Head - 3 Phase

    2048321/29991402

    Wilo - TOP-S 25/7 REPLACEMENT Head - 400V - 3 Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £650.40 RRP £422.76 £352.30
    In Stock In stock
    Delivery Icon Free Standard Delivery
  15. Wilo TOP-S 25/7 Replacement Head - Single Phase

    2048334/29991401

    Wilo - TOP-S 25/7 REPLACEMENT Head - 230V - Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £585.60 RRP £380.64 £317.20
    In Stock In stock
    Delivery Icon Free Standard Delivery
  16. Wilo TOP-S 30/7 Replacement Head - Single Phase

    2048336/29991408

    Wilo - TOP-S 30/7 REPLACEMENT Head - 230V - Single Phase

    Please ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.

    Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.

    Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.

    Item includes:

    Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.

    Advantages:

    Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.

    Tech Info
    • Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
    • Mains connection:
      • 1~230 V, 50 Hz (depending on type)
      • 3~230 V, 50 Hz (with optional switching plug)
      • 3~400 V, 50 Hz
    • Protection class IP X4D
    • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
    • Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
    Materials
    • Pump housing: Grey Cast Iron
    • Impeller: Plastic
    • Shaft: Stainless Steel
    • Bearing: Carbon, metal impregnated
    Construction:

    Glandless circulation pump with screwed connection or flange connection.

    Application

    Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits

    Equipment/function

    Operating modes

    • Speed-stage switching

    Manual functions

    • Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)

    Automatic functions

    • Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)

    Signal and display functions

    • Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
    • Direction of rotation control light (only for 3~pumps )
    • Display of selected speed stage

    Dual pump management (twin-head pump or 2 x single pumps)

    • Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)

    Equipment

    • For flange-end pumps: Flange versions
      • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
      • Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
    • Thermal insulation as standard for heating applications
    Type key

    Example:

    TOPS 40/10

    TOP-S

    Standard pump (screw-end pump or flange-end pump)

    40/

    Nominal connection diameter

    10

    Nominal delivery head [m] at Q = 0 m3/ h

    £648.00 RRP £421.20 £351.00
    In Stock In stock
    Delivery Icon Free Standard Delivery
View as Grid List

86 Items

Page
per page
Filter Products
Set Descending Direction
Heating Circulators

Heating Circulators

Heating circulator pumps keep hot water moving through radiators, baseboards, and underfloor heating systems. They ensure your heating system delivers warmth quickly, reduces waiting times for hot water, and keeps energy use under control.

 

Whether used individually or in combination, circulator pumps can serve multiple zones, giving precise control over each area of your property. In multi-zone systems, one circulator can serve all areas using control valves for each section, or you can fit a dedicated pump to each zone for precise, independent flow.

 

Modern circulators save significant power while maintaining consistent flow. Pumpify offers a range of trusted models from big name brands that are built for durability, smooth operation, and long-lasting performance, helping you get the most out of your heating system.