By Range
-
ZI-11A0020000
Zilmet - Hydro-Pro Vertical Expansion Vessel - 10 Bar. - 200LtrZilmet Hydro-Pro Vertical Expansion Vessel - 10 Bar. - 200Ltr Zilmet HYDRO‑PRO pressure vessels are designed for potable water and booster systems where stable pressure and efficient pump.
In stock
Free Standard Delivery
-
ZI-1300020000
Zilmet - Cal-Pro Vertical Expansion Vessel - 6 Bar. - 200LtrZilmet Cal-Pro Vertical Expansion Vessel - 6 Bar. - 200Ltr Zilmet CAL‑PRO expansion vessels are designed for sealed heating systems to absorb thermal expansion as water temperature increases.
In stock
Free Standard Delivery
-
16193
Flamco - 200 Ltr - Flexcon Top Expansion Vessel - 10 barFlamco Flexcon Expansion Vessel - 200Ltr - Engineered for EN 12828 heating and chilled-water systems, this Expansion Vessel stabilises sealed system pressure by absorbing thermal expansion in LPHW/CHW applications.
Maximum working pressure: 10.0 bar.
Vessels in accordance with EN13831.
Suitable for systems with a maximum system temperature of 120 °C.
Minimum/maximum temperature diaphragm: -10 / 90 °C.
Suitable for addition of glycol-based anti-freeze up to 50%.
A flexible rolling diaphragm with a ribbed profile prevents sticking and encourages inflow at the slightest pressure rise, while a nitrogen pre-charge helps maintain set pressure longer. The uncoated connection thread supports quick, watertight installation.
- Rolling-diaphragm design for smooth expansion control
- Nitrogen pre-charge for extended pre-pressure retention
- Top-quality steel with epoxy-powder finish
- Factory tested for reliability
Built for long service life in domestic, commercial and industrial plant rooms, with continuous medium temperatures from −10 to 70 C.
In stock
Free Standard Delivery
-
16293
Flamco - 300 Ltr - Flexcon Top Expansion Vessel - 10 barFlamco Flexcon Expansion Vessel - 300Ltr - Engineered for EN 12828 heating and chilled-water systems, this Expansion Vessel stabilises sealed system pressure by absorbing thermal expansion in LPHW/CHW applications.
Maximum working pressure: 10.0 bar.
Vessels in accordance with EN13831.
Suitable for systems with a maximum system temperature of 120 °C.
Minimum/maximum temperature diaphragm: -10 / 90 °C.
Suitable for addition of glycol-based anti-freeze up to 50%.
A flexible rolling diaphragm with a ribbed profile prevents sticking and encourages inflow at the slightest pressure rise, while a nitrogen pre-charge helps maintain set pressure longer. The uncoated connection thread supports quick, watertight installation.
- Rolling-diaphragm design for smooth expansion control
- Nitrogen pre-charge for extended pre-pressure retention
- Top-quality steel with epoxy-powder finish
- Factory tested for reliability
Built for long service life in domestic, commercial and industrial plant rooms, with continuous medium temperatures from −10 to 70 C.
In stock
Free Standard Delivery
-
22002
Flamco - 300 Ltr - Flexcon M Expansion Vessel - 3-6 BarFlamco Flexcon M Expansion Vessel - 300Ltr - 3-6 bar. - Tailored for sealed heating and chilled-water systems, the Flexcon M 100/3.0 [6Bar] is a replaceable-bladder expansion vessel designed to stabilise pressure in accordance with EN 12828.
It excels where static pressure and safety-valve setpoint differ significantly, helping maintain pre-pressure while minimising cycling. Supplied ready to install with a pressure gauge and height-adjustable feet, plus an inspection flange for servicing.
- Replaceable butyl bladder for fast maintenance
- Pressure gauge and height-adjustable feet included
- Inspection flange for internal access
- Robust steel vessel with durable epoxy-powder finish
- Uncoated connection thread for easy, watertight installation
For larger models (12008000 Ltrs), a Flexvent Super can be fitted to enhance air removal.
In stock
Free Standard Delivery
-
22011
Flamco - 200 Ltr - Flexcon M Expansion Vessel - 6-10 BarBuilt for sealed heating and chilled-water circuits, the Flexcon M [10Bar] is a replaceable-bladder expansion vessel designed to stabilise system pressure in line with EN 12828.
It excels where static pressure and safety-valve setpoint differ significantly, helping maintain pre-pressure while reducing cycling. Supplied with a pressure gauge, height-adjustable feet and an inspection flange for straightforward servicing.
- Replaceable bladder for fast maintenance and long service life
- Delivered ready to install: gauge and adjustable feet included
- Inspection flange for internal access
- Robust steel vessel with durable epoxy-powder finish
Larger Flexcon M models (12008000 Ltrs) can be fitted with a Flexvent Super for enhanced air removal.
In stock
Free Standard Delivery
Vessels
Vessels are key to keeping water and heating systems safe, reliable, and running efficiently. They help manage pressure, protect components, and make sure everything works smoothly day after day. At Pumpify, we offer vessels from top manufacturers like Flamco, Mikrofill, Stuart Turner, and Zilmet, so you can pick the right option with confidence.
From classic pressure and expansion vessels that balance system pressure to smart heating vessels that adjust automatically, there’s a solution for every setup. Maybe a flow-through vessel to keep water moving and prevent stagnation is what you need, or a potable water vessel for safe drinking water storage and regulation suits your project better.
With Pumpify, it’s easy to find the right vessel, helping your projects run smoothly and efficiently, every time.


















