WI-2120666
Wilo - Yonos Maxo-D 40/0.5-16 PN6/10 Circulator Pump - 230V - Single Phase - 250mmHigh-efficiency pump Wilo-Yonos MAXO-D, electronically controlled. Glandless twin-head pump, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Each pump can be operated in individual operation (main/standby operation). The connection module Yonos MAXO can be utilised for automatic fault-actuated switchover.
Standard-equipped with:
In stock
Free Standard Delivery
-
WI-2120667
Wilo - Yonos Maxo-D 50/0.5-9 PN6/10 Circulator Pump - 230V - Single Phase - 280mmHigh-efficiency pump Wilo-Yonos MAXO-D, electronically controlled. Glandless twin-head pump, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Each pump can be operated in individual operation (main/standby operation). The connection module Yonos MAXO can be utilised for automatic fault-actuated switchover.
Standard-equipped with:
In stock
Free Standard Delivery
-
WI-2120668
Wilo - Yonos Maxo-D 50/0.5-12 PN6/10 Circulator Pump - 230V - Single Phase - 280mmHigh-efficiency pump Wilo-Yonos MAXO-D, electronically controlled. Glandless twin-head pump, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Each pump can be operated in individual operation (main/standby operation). The connection module Yonos MAXO can be utilised for automatic fault-actuated switchover.
Standard-equipped with:
In stock
Free Standard Delivery
-
WI-2120669
Wilo - Yonos Maxo-D 50/0.5-16 PN6/10 Circulator Pump - 230V - Single Phase - 340mmHigh-efficiency pump Wilo-Yonos MAXO-D, electronically controlled. Glandless twin-head pump, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Each pump can be operated in individual operation (main/standby operation). The connection module Yonos MAXO can be utilised for automatic fault-actuated switchover.
Standard-equipped with:
In stock
Free Standard Delivery
-
WI-2120670
Wilo - Yonos Maxo-D 65/0.5-12 PN6/10 Circulator Pump - 230V - Single Phase - 340mmHigh-efficiency pump Wilo-Yonos MAXO-D, electronically controlled. Glandless twin-head pump, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Each pump can be operated in individual operation (main/standby operation). The connection module Yonos MAXO can be utilised for automatic fault-actuated switchover.
Standard-equipped with:
In stock
Free Standard Delivery
-
WI-2120671
Wilo - Yonos Maxo-D 65/0.5-16 PN6/10 Circulator Pump - 230V - Single Phase - 340mmHigh-efficiency pump Wilo-Yonos MAXO-D, electronically controlled. Glandless twin-head pump, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Each pump can be operated in individual operation (main/standby operation). The connection module Yonos MAXO can be utilised for automatic fault-actuated switchover.
Standard-equipped with:
In stock
Free Standard Delivery
-
WI-2120672
Wilo - Yonos Maxo-D 80/0.5-12 PN6 Circulator Pump - 230V - Single Phase - 360mmHigh-efficiency pump Wilo-Yonos MAXO-D, electronically controlled. Glandless twin-head pump, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Each pump can be operated in individual operation (main/standby operation). The connection module Yonos MAXO can be utilised for automatic fault-actuated switchover.
Standard-equipped with:
In stock
Free Standard Delivery
-
WI-2120673
Wilo - Yonos Maxo-D 80/0.5-12 PN10 - Circulator Pump - 230V - Single Phase - 360mmHigh-efficiency pump Wilo-Yonos MAXO-D, electronically controlled. Glandless twin-head pump, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Each pump can be operated in individual operation (main/standby operation). The connection module Yonos MAXO can be utilised for automatic fault-actuated switchover.
Standard-equipped with:
In stock
Free Standard Delivery
-
WIL-2120652
Wilo - Yonos Maxo 50/0.5-16 Circulator Pump - 230V - Single Phase - 340mmHigh efficiency pump Wilo-Yonos MAXO
High efficiency light commercial circulator pump with 8m max head, 220 mm port-to-port length and DN40 flanged connections.
The Wilo Yonos MAXO range are high efficiency glandless light commercial circulator pumps developed to enable quick and simple installation.
They can be used in many types of closed circuits including central heating, air conditioning and industrial applications.
The Yonos MAXO-D pumps are twin head units.
is an electronically controlled,
Glandless circulator, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Standard-equipped with:
In stock
Free Standard Delivery
-
2085909
Wilo - Press Sensor - 1/4 inch - 0-16 Bar.Wilo - PRESS.SENSOR 1/4" 0-16BA. Image for Illustration purposes only.
In stock
Free Standard Delivery
-
2045521
Wilo - TOP-Z 25/6 - Domestic Hot Water Circulator - Single Phase - Obsolete - 180mmApplicationDomestic Hot water circulation systems in industry and building services.
Equipment/functionOperating modes
Speed-stage switching.
Manual functions
Setting the speed stages: 3 speed stages.
Automatic functions
- Internal protection against unacceptably high winding temperatures (only for pumps with P2 < 180 W, optional for all types with switchgears SK 602N and SK 622N)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) (only for pumps with P2 ≥ 180 W)
- Direction of rotation signal lamp (only for 3~ pumps)
Example:
Wilo-TOP-Z 40/7
TOP
Standard pump (screw-end pump or flange-end pump)
šªZ
Single pump for domestic Hot water circulation
40/
Nominal connection diameter
7
Nominal delivery head range [m] at Q = 0 m3/h
Out Of StockFree Standard Delivery
-
2048340
Wilo - TOP-Z 30/7 - Domestic Hot Water Circulator - 230V - Single Phase - Threaded Connection - 180mmThis circulator is suitable only for drinking water.
can be utilised for domestic Hot water circulation systems in the industry and building services.
Glandless circulator with screwed or flange connection, preselectable speed stages for power adjustment.
Equipment and function
In stock
Free Standard Delivery
-
WIL-2120649
Wilo - Yonos Maxo 50/0.5-8 Circulator Pump - 230V - Single Phase - 240mmHigh efficiency pump Wilo-Yonos MAXO
High efficiency light commercial circulator pump with 8m max head, 220 mm port-to-port length and DN40 flanged connections.
The Wilo Yonos MAXO range are high efficiency glandless light commercial circulator pumps developed to enable quick and simple installation.
They can be used in many types of closed circuits including central heating, air conditioning and industrial applications.
The Yonos MAXO-D pumps are twin head units.
is an electronically controlled,
Glandless circulator, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Standard-equipped with:
In stock
Free Standard Delivery
-
2120654
Wilo - Yonos Maxo 65/0.5-12 Circulator Pump - 230V - Single Phase - 340mmHigh efficiency pump Wilo-Yonos MAXO
High efficiency light commercial circulator pump with 8m max head, 340 mm port-to-port length and DN65 flanged connections.
The Wilo Yonos MAXO range are high efficiency glandless light commercial circulator pumps developed to enable quick and simple installation.
They can be used in many types of closed circuits including central heating, air conditioning and industrial applications.
The Yonos MAXO-D pumps are twin head units.
is an electronically controlled,
Glandless circulator, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Standard-equipped with:
In stock
Free Standard Delivery
-
2531400
Wilo - Drainlift M2-8 RV Sewage Lifting Unit - 230V - Single PhaseReady-for-connection, fully submersible and automatic sewage lifting unit as a double pump system with automatic duty cycling, standby and peak-load operation. Dry motor in single-phase version with Stainless Steel housing and thermal motor monitoring.
Gas-tight and water-tight collection reservoir made from plastic with tapering collection chamber for dependable operation without any build-up of deposits, freely selectable inlets and a level control device with a rod float switch.
Central pressure connection with integrated Y-pipe, non-return valve, and lifting device.
Microprocessor-controlled switchgear with:
- LEDs for displaying operating status and error messages
- Adjustable run-on time
- Integrated and mains-independent alarm
- 1x potential-free contact for connection of a collective fault signal (SSM)
Scope of delivery:
- Sewage lifting unit ready for connection with switchgear and plug
- 1x inlet seal DN 100
- 1x hole saw for inlet DN 100
- 1x lip seal for connection of diaphragm hand pump or inlet connection Ø 50 mm
- 1x collar for ventilation connection DN 70
- 1x flange connector DN 80/100 with flat gasket, flexible hose section and fixing material for pressure connection DN 100
- 9 V rechargeable battery
- 11x sound absorption strips for sound insulation Installation manual
- Fixation material
Operating Data:
Fluid to be pumped : Water 100 %
Fluid temperature : 20 °C
Delivery head at Q=0 : 8,50 m
Permitted field of application:
Max. ambient temperature : 40 °C
Min. fluid temperature : 3 °C
Max. fluid temperature : 40 °C
Max. fluid temperature, for short periods up to 3 min : 60 °C
Maximum operating pressure : 1,5 bar.
Max. permissible pressure in the pressure pipe : 150 kPa Unit
Gross volume : 115 l
Max. switching volume : 40 l
Inlet connection : DN 40/DN 100/DN 150
Pressure connection : DN 80
Venting : DN 70
Operating mode per pump : S3-15%, 80 sec
Min. level ON : 180 mm
Dimensions : 810 x 505 x 780 mm
Diagonal dimension : 970 mm
Weight approx. : 91 kgMotor
Mains connection : 1~230V/50 Hz
Power consumption P1 : 1,3 kW
Rated speed : 2900 1/min
Rated current : 5,8 A
In stock
Free Standard Delivery
-
4035477
Wilo - SB 5Y Bronze Circulator Pump - 230V - Single Phase - 130mmThis circulation pump is suitable only for drinking water.
Domestic Hot water circulation pump, glandless pump with manual three-stage speed control for pipe installation.
Blocking current-proof motor Pump housing made of bronze, impeller made of fibreglass-reinforced plastic, ceramic shaft with resin-impregnated carbon friction bearings.
6 week lead time