-
2186285
Wilo - Stratos Maxo 80/0,5-12 PN16 Glandless Circulator Pump - 230V - Single Phase - 1117 Ltr/min. - 360mmPremium smart-pump Wilo-Stratos MAXO
High-efficiency in-line glandless pump with EC motor and electronic power adjustment. can be utilised for chilled water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between ⤠0.17 and ⤠0.19 depending on pump type.
Control modes:
In stock
Free Standard Delivery
-
2186288
Wilo - Stratos Maxo 100/0,5-12 PN16 Glandless Circulator Pump - 230V - Single Phase - 1117 Ltr/min. - 360mmPremium smart-pump Wilo-Stratos MAXO
High-efficiency in-line glandless pump with EC motor and electronic power adjustment. can be utilised for chilled water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between ⤠0.17 and ⤠0.19 depending on pump type.
Control modes:
In stock
Free Standard Delivery
-
99132859
Grundfos - TPED 100-90/4 S-A-F-A-BQQE-IDA Twin Head In-Line Centrifugal Pump - 415V - Three Phase - 1968 Ltr/min. - Cast IronTPED 100-90/4 S-A-F-A-BQQE-IWA
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with a differential pressure sensor.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Cast Iron
- Maximum operating pressure: 16 Bar.
- Temperature liquid range: -25 .. 120 °C.
In stock
Free Standard Delivery
-
99114631
Grundfos - TPED 100-90/4 A-F-A-BQQE-IDA Twin Head Centrifugal Pump - 415V - Three Phase - 1968 Ltr/min. - Cast IronTPED 100-90/4 A-F-A-BQQE-IWA
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98742800
Grundfos - TPE 50-630/2 A-F-A-BQQE-OX1 Variable Speed In-Line Circulator Pump - 415V - Three Phase - 1200 Ltr/min. - Cast IronTPE 50-630/2 A-F-A-BQQE-OW1
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99114668
Grundfos - TPE 50-540/2 S-A-F-A-BQQE-NDB Variable Speed In-Line Circulator Pump - 415V - Three Phase - 1167 Ltr/min. - Cast IronTPE 50-540/2 S-A-F-A-BQQE-NWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
96109368
Grundfos - TPD 100-130/4 A-F-A-BQQE-KX3 Inline Twin Head Circulator Pump - 725v - Three Phase - Cast IronTPD 100-130/4 A-F-A-BQQE-KW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
1 week lead time
Free Standard Delivery
-
96087589
Grundfos - TPD 65-720/2 A-F-A-BQQE-QX1 Inline Twin Head Circulator Pump - 690v - Three Phase - Cast IronTPD 65-720/2 A-F-A-BQQE-QW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
1 week lead time
Free Standard Delivery
-
96108895
Grundfos - TPD 80-270/4 A-F-A-BQQE-MX3 Inline Twin Head Circulator Pump - 725v - Three Phase - Cast IronTPD 80-270/4 A-F-A-BQQE-MW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
1 week lead time
Free Standard Delivery
-
96096606
Grundfos - TPE 65-660/2 A-F-A-BQQE-PX1 Inline Single Stage Circulator Pump - 480v - Three Phase - Cast IronTPE 65-660/2 A-F-A-BQQE-PW1
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
-
96397052
Grundfos - TPE 65-660/2 S-A-F-A-BQQE-PX1 Inline Single Stage Circulator Pump - 480v - Three PhaseTPE 65-660/2 S-A-F-A-BQQE-PW1
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled asynchronous motor. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
96096661
Grundfos - TPED 65-720/2 A-F-A-BQQE-QX1 Inline Twin Head Circulator Pump - 480v - Three Phase - Cast IronTPED 65-720/2 A-F-A-BQQE-QW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
-
96945793
Grundfos - TPED 65-720/2 S-A-F-A-BQQE-QX1 Inline Twin Head Circulator Pump - 480v - Three Phase - Cast IronTPED 65-720/2 S-A-F-A-BQQE-QW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
99114629
Grundfos - TPED 80-270/4 A-F-A-BQQE-MDA Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPED 80-270/4 A-F-A-BQQE-MWA
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
-
99132857
Grundfos - TPED 80-270/4 S-A-F-A-BQQE-MDA Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPED 80-270/4 S-A-F-A-BQQE-MWA
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
E510150AA
Lowara - Ecocirc XL Plus N 50-120 F Circulating Pump - Single Phase - 230V - 1170 Ltr/minAdvanced Control Modes
In stock
Free Standard Delivery
Circulating Pumps
Circulating pumps move slurries, liquids, and gases through a closed system, keeping heating, cooling, and hot water circuits flowing as they should. They are most commonly used in domestic and commercial heating systems to maintain a steady supply of hot water, but they also play a key role in underfloor heating, radiator circuits, and chilled water applications.
By keeping water moving continuously, circulating pumps help balance temperatures, reduce energy waste, and ensure that taps, showers, and heating systems respond instantly when needed. Hot water circulating pumps are particularly useful in larger properties or commercial setups, where waiting for water to heat can lead to unnecessary water and energy use.
At Pumpify, our range includes circulating pumps suitable for everything from simple domestic setups to more complex commercial systems. Designed for easy installation, straightforward maintenance, and long-term performance, these pumps ensure your heating and hot water systems operate smoothly, reliably, and cost-effectively.















