-
2164595
Wilo - Stratos Maxo 65/0,5-16 PN6/10 Glandless Circulator Pump - 230V - Single Phase - 900 Ltr/min. - 340mmPremium smart-pump Wilo-Stratos MAXO
High-efficiency in-line glandless pump with EC motor and electronic power adjustment. can be utilised for chilled water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between ⤠0.17 and ⤠0.19 depending on pump type.
Control modes:
In stock
Free Standard Delivery
-
2186279
Wilo - Stratos Maxo 50/0,5-16 PN16 Glandless Circulator Pump - 230V - Single Phase - 884 Ltr/min. - 340mmPremium smart-pump Wilo-Stratos MAXO
High-efficiency in-line glandless pump with EC motor and electronic power adjustment. can be utilised for chilled water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between ⤠0.17 and ⤠0.19 depending on pump type.
Control modes:
In stock
Free Standard Delivery
-
2186283
Wilo - Stratos Maxo 65/0,5-16 PN16 Glandless Circulator Pump - 230V - Single Phase - 900 Ltr/min. - 340mmPremium smart-pump Wilo-Stratos MAXO
High-efficiency in-line glandless pump with EC motor and electronic power adjustment. can be utilised for chilled water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between ⤠0.17 and ⤠0.19 depending on pump type.
Control modes:
In stock
Free Standard Delivery
-
96110246
Grundfos - TPED 80-340/4 A-F-A-BQQE-NX3 Twin Head In-Line Circulator Pump - 415V - Three Phase - 1834 Ltr/min. - Cast IronTPED 80-340/4 A-F-A-BQQE-NW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99114625
Grundfos - TPED 65-240/4 A-F-A-BQQE-KDA Twin Head In-Line Circulator Pump - 415V - Three Phase - 900 Ltr/min. - Cast IronTPED 65-240/4 A-F-A-BQQE-KWA
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98437897
Grundfos - TPE2 50-240 N-A-F-A-BQQE-IDC Variable Speed In-Line Circulator Pump - 415V - Three Phase - 884 Ltr/min. - Cast IronTPE2 50-240 N-A-F-A-BQQE-IYC
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99272219
Grundfos - TPE3 50-240 S-A-F-A-BQQE-IDC Variable Speed In-Line Circulator Pump - 415V - Three Phase - 884 Ltr/min. - Cast IronTPE3 50-240 S-A-F-A-BQQE-IYC
Single-stage, close-coupled, volute Pump with in-line suction and discharge ports of identical diameter. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The Pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The Pump is equipped with a fan-cooled asynchronous motor. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
In stock
Free Standard Delivery
-
98416723
Grundfos - TPE3 50-240 S-A-F-I-BQQE-IDC Variable Speed In-Line Circulator Pump - 415V - Three Phase - 884 Ltr/min. - Stainless SteelTPE3 50-240 S-A-F-I-BQQE-IYC
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
99114662
Grundfos - TPE 40-630/2 S-A-F-A-BQQE-NDB Variable Speed In-Line Circulator Pump - 415V - Three Phase - 900 Ltr/min. - Cast IronTPE 40-630/2 S-A-F-A-BQQE-NWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
96087256
Grundfos - TPD 50-830/2 A-F-A-BQQE-PX1 Inline Twin Head Circulator Pump - 415V - Three Phase - Cast IronSuitable for: Commercial air conditioning
Grundfos TPD pumps are single-stage, close-coupled in-line centrifugal twin-head pumps with mechanical shaft seal and primally for applications such as heating/cooling/district energy.
The pumps are fitted with fixed speed motors.
1 week lead time
Free Standard Delivery
-
96108893
Grundfos - TPD 80-170/4 A-F-A-BQQE-KX3 Inline Twin Head Circulator Pump - 725v - Three Phase - Cast IronTPD 80-170/4 A-F-A-BQQE-KW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
1 week lead time
Free Standard Delivery
-
96108789
Grundfos - TPD 80-210/2 A-F-A-BQQE-KX1 Inline Twin Head Circulator Pump - 415V - Three Phase - Cast IronTPD 80-210/2 A-F-A-BQQE-KW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
2-3 day delivery
Free Standard Delivery
-
99113942
Grundfos - TPE 65-250/2 A-F-A-BQQE-KDB Inline Single Stage Circulator Pump - 500v - Three Phase - Cast IronTPE 65-250/2 A-F-A-BQQE-KWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99114670
Grundfos - TPE 65-250/2 S-A-F-A-BQQE-KDB Inline Single Stage Circulator Pump - 500v - Three Phase - Cast IronTPE 65-250/2 S-A-F-A-BQQE-KWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
96096501
Grundfos - TPED 50-830/2 A-F-A-BQQE-PX1 Inline Twin Head Circulator Pump - 480v - Three Phase - Cast IronTPED 50-830/2 A-F-A-BQQE-PW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
2 week lead time
Free Standard Delivery
-
96945778
Grundfos - TPED 50-830/2 S-A-F-A-BQQE-PX1 Inline Twin Head Circulator Pump - 480v - Three Phase - Cast IronTPED 50-830/2 S-A-F-A-BQQE-PW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
Circulating Pumps
Circulating pumps move slurries, liquids, and gases through a closed system, keeping heating, cooling, and hot water circuits flowing as they should. They are most commonly used in domestic and commercial heating systems to maintain a steady supply of hot water, but they also play a key role in underfloor heating, radiator circuits, and chilled water applications.
By keeping water moving continuously, circulating pumps help balance temperatures, reduce energy waste, and ensure that taps, showers, and heating systems respond instantly when needed. Hot water circulating pumps are particularly useful in larger properties or commercial setups, where waiting for water to heat can lead to unnecessary water and energy use.
At Pumpify, our range includes circulating pumps suitable for everything from simple domestic setups to more complex commercial systems. Designed for easy installation, straightforward maintenance, and long-term performance, these pumps ensure your heating and hot water systems operate smoothly, reliably, and cost-effectively.















