-
99272535
Grundfos - TPE3 D 80-120 S-A-F-A-BQQE-GAB Inline Twin Head Circulator Pump - 240V - Single Phase - Cast IronTPE3 D 80-120 S-A-F-A-BQQE-GWB
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272527
Grundfos - TPE3 D 80-120 S-A-F-A-BQQE-GDB Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 80-120 S-A-F-A-BQQE-GWB
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272536
Grundfos - TPE3 D 80-150 S-A-F-A-BQQE-HAB Inline Twin Head Circulator Pump - 240V - Single Phase - Cast IronTPE3 D 80-150 S-A-F-A-BQQE-HWB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
99272528
Grundfos - TPE3 D 80-150 S-A-F-A-BQQE-HDB Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 80-150 S-A-F-A-BQQE-HWB
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272529
Grundfos - TPE3 D 80-180 S-A-F-A-BQQE-IDB Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 80-180 S-A-F-A-BQQE-IWB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
99272534
Grundfos - TPE3 D 80-40 S-A-F-A-BQQE-CAA Inline Twin Head Circulator Pump - 240V - Single Phase - Cast IronTPE3 D 80-40 S-A-F-A-BQQE-CYA
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99272526
Grundfos - TPE3 D 80-40 S-A-F-A-BQQE-CDA Inline Twin Head Circulator Pump - 500v - Three Phase - Cast IronTPE3 D 80-40 S-A-F-A-BQQE-CYA
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
2 week lead time
Free Standard Delivery
-
99133716
Grundfos - TPED 100-120/2 S-A-F-A-BQQE-IDB Inline Twin Head Circulator Pump - 500v - Three PhaseTPED 100-120/2 S-A-F-A-BQQE-IWB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
2 week lead time
Free Standard Delivery
-
98957942
Grundfos - TP 32-30/4 A-F-A-BQQE-AW3 Single Head Inline Circulator Pump - 230V - Single Phase - 98 Ltr/min.TP 32-30/4 A-F-A-BQQE-AW3
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
Gr-97924284
Grundfos - Magna3 50-120F 97924284 Variable Speed Circulator - 230V - Stainless SteelMAGNA3 50-120 F
The Grundfos MAGNA3 circulator pump is the well-suited choice for almost any building project – old or new. With its unrivalled energy efficiency, all-encompassing range and built-in communication capabilities, MAGNA3 is well-suited for engineers and specifiers looking to create high-performance heating and cooling systems. The pump is maintenance-free due to the canned-rotor type design. This also means that pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. MAGNA3 features an intuitive display and allows you to connect wirelessly with the Grundfos GO Remote app, giving you access to enhanced reporting and monitoring. MAGNA3 model E has Bluetooth, which allows you to connect directly to the Grundfos GO app on your smart phone without any need for a dongle. The pump includes fieldbus communication via CIM modules as well as analogue and digital inputs and configurable relays. Control features include AUTOADAPT and FLOWADAPT. FLOWADAPT reduces the need for throttling valves, thus cutting costs on system components. MAGNA3 is the superior choice for a wide range of heating and cooling applications, including:
MAGNA3 is a single-phase pump characterised by the controller and control display being integrated in the control box. The pump also has a built-in differential pressure and temperature sensor. The pump housing is available in both cast-iron and stainless-steel versions. The composite rotor can is carbon-fibre reinforced, the bearing plate and rotor cladding are made of Stainless Steel and the stator housing is made of aluminium. The power electronics are air-cooled. MAGNA3 incorporates a 4-pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. The pump speed is controlled by an integrated frequency converter.- small chiller applications
- ground-source heat pump systems
- air conditioning surfaces
- heating surfaces
- mixing loops
Suitable for: Commercial heating
In stock
Free Standard Delivery
-
GR-98958116
Grundfos - TP 32-180/2 0.55kw 2900RPM Commercial Circulator Pump - Single Head - 230V - 0.55kWTP 32-180/2 A-F-A-BQQE-EW1
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
2046663
Wilo - TOP-S 30/10 REPLACEMENT Head - 230V -Single PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046665
Wilo - TOP-S 40/7 REPLACEMENT Head - 230V - Single PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046666
Wilo - TOP-S 40/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046668
Wilo - TOP-S 50/4 REPLACEMENT Head - 230V - Single PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046672
Wilo - TOP-S 50/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
Heating Circulators
Heating circulator pumps keep hot water moving through radiators, baseboards, and underfloor heating systems. They ensure your heating system delivers warmth quickly, reduces waiting times for hot water, and keeps energy use under control.
Whether used individually or in combination, circulator pumps can serve multiple zones, giving precise control over each area of your property. In multi-zone systems, one circulator can serve all areas using control valves for each section, or you can fit a dedicated pump to each zone for precise, independent flow.
Modern circulators save significant power while maintaining consistent flow. Pumpify offers a range of trusted models from big name brands that are built for durability, smooth operation, and long-lasting performance, helping you get the most out of your heating system.















