GR-98057242
Grundfos - UPS 40-50FN Domestic Hot Water Circulator Pump - Stainless SteelUPS 40-50 FN 250
The pump unit is of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricatd by the pumped liquid. The pump has 3-step speed selector. The pump is characterized by:
- Stainless Steel pump housing
- corrosion-protected impeller, Composite
- Stainless Steel rotor can and bearing plate
- Carbon axial bearing
- Ceramic shaft and radial bearings
The motor is a 1-phase motor. No additional motor protection is required.
Suitable for: Commercial heating, Domestic heating, Domestic hot water recirculation
In stock
Free Standard Delivery
-
GR-96401942-97924178/99221305
Grundfos - UPS 40-120/2 (250) Single Head Commercial Circulator 240V replaced with MAGNA1C 40-120F (250)The Grundfos MAGNA1 40-120F (250) 'A' Rated/EuP Ready variable speed circulator pumps are designed for circulating liquids in heating systems with variable flows and also for domestic hot-water systems with easy selection of pump setting, no maintenance requirements and extremely low life cycle cost.
In stock
Free Standard Delivery
-
GR-98057249
Grundfos - UPS 32-100N Hot Water Service Circulator - 240V - Stainless SteelUPS 32-100 N 180
The pump unit is of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricatd by the pumped liquid. The pump has 3-step speed selector. The pump is characterized by:
- Stainless Steel pump housing
- corrosion-protected impeller, Composite
- Stainless Steel rotor can and bearing plate
- Carbon axial bearing
- Ceramic radial bearing assembly
- Stainless Steel shaft
The motor is a 1-phase motor. No additional motor protection is required.
Suitable for: Commercial heating, Domestic heating, Domestic hot water recirculation
In stock
Free Standard Delivery
-
GR-98057227
Grundfos - UPS 25-80N (180) Hot Water Circulator Pump - 240V - Stainless SteelUPS 25-80 N 180
The pump unit is of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricatd by the pumped liquid. The pump has 3-step speed selector. The pump is characterized by:
- Stainless Steel pump housing
- corrosion-protected impeller, Composite
- Stainless Steel rotor can and bearing plate
- Carbon axial bearing
- Ceramic shaft and radial bearings
The motor is a 1-phase motor. No additional motor protection is required.
Suitable for: Commercial heating, Domestic heating, Domestic hot water recirculation
In stock
Free Standard Delivery
-
GR-96281476-98334549
Grundfos - UPS 25-60 (130mm) Domestic Circulator Pump 240V - OBSOLETEThis pump has now been replaced with the NEW UPS3 15-50/65 CLICK HERE
In stock
Free Standard Delivery
-
GR-95906772
Grundfos - UPS 25-55N Hot Water Service Circulator - 240V - Stainless SteelUPS 25-55 N 180
The pump unit is of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricatd by the pumped liquid. The pump has 3-step speed selector. The pump is characterized by:
- Stainless Steel pump housing
- corrosion-protected impeller, Composite
- Stainless Steel rotor can and bearing plate
- Carbon axial bearing
- Ceramic shaft and radial bearings
The motor is a 1-phase motor. No additional motor protection is required.
Suitable for: Commercial heating, Domestic heating, Domestic hot water recirculation
In stock
Free Standard Delivery
-
2046664
Wilo - TOP-S 30/10 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
3 week lead time
Free Standard Delivery
-
2046666
Wilo - TOP-S 40/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046672
Wilo - TOP-S 50/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046674
Wilo - TOP-S 50/15 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046675/29991433
Wilo - TOP-S 65/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046676 / 29991437
Wilo - TOP-S 65/10 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
WILO-29991442
Wilo - TOP-S 80/10 REPLACEMENT Head - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
96405855
Grundfos - UPC/D 40-120 and UPS/D 32-120/2, 40-60/4, 50-60/2 Replacement Termin.al Box - 240VService special
In stock
Free Standard Delivery
-
96405853
Grundfos - UPC/D 40-60 and UPS/D 32-60/2, 40-30/4, 50-30/4 Replacement Termin.al Box - 240VService special
In stock
Free Standard Delivery
-
In stock
Free Standard Delivery
Spares
From pump heads and non-return valves to terminal boxes or full units, our spares fit straight in, cutting downtime and keeping your project on track.
We’re so confident in their quality, every spare comes with a one-year guarantee. Not sure which part you need? Our friendly team is ready to help, fast and hassle-free, so you can get back to what you do best.