2046664
Wilo - TOP-S 30/10 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
3 week lead time
Free Standard Delivery
-
2046666
Wilo - TOP-S 40/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046672
Wilo - TOP-S 50/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046673
Wilo - TOP-S 50/10 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046674
Wilo - TOP-S 50/15 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046675/29991433
Wilo - TOP-S 65/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2046676 / 29991437
Wilo - TOP-S 65/10 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
WILO-29991442
Wilo - TOP-S 80/10 REPLACEMENT Head - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
2048321/29991402
Wilo - TOP-S 25/7 REPLACEMENT Head - 400V - 3 PhasePlease ensure Top-S replacement head part is appropriate for your pump model. Replacement heads unfortunately CANNOT be returned if they have been attempted to be fitted. If unsure please contact 0800 008 6405.
Can be utilised for Hot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits.
Maintenance-free glandless circulation pump with threaded or flange connection, pre-selectable speed stages for power adjustment.
Item includes:Pump, Thermal insulation, Including seals for threaded connection, Washers for flange screws (for nominal connection diameters DN 40 - DN 65), and Installation manual and operating instructions.
Advantages:
Direction of rotation signal lamp for displaying the correct sense of rotation (only with 3~), Manual power adjustment with 3 speed stages, and Pump housing with cataphoretic coating (KTL) protects against corrosion due to condensation formation.
Tech Info- Permitted temperature range -20 C to +130 C, for short periods (2 h) to +140 C (TOP-S 25/13, 80/15, 80/20: -20 C to +110 C)
- Mains connection:
- 1~230 V, 50 Hz (depending on type)
- 3~230 V, 50 Hz (with optional switching plug)
- 3~400 V, 50 Hz
- Protection class IP X4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure of standard version: 6/10 bar. or 6 bar. (special version: 10 bar.)
Materials- Pump housing: Grey Cast Iron
- Impeller: Plastic
- Shaft: Stainless Steel
- Bearing: Carbon, metal impregnated
Construction:Glandless circulation pump with screwed connection or flange connection.
ApplicationHot-water heating systems of all sorts, industrial circulation systems, air-conditioning systems and closed cooling circuits
Equipment/functionType keyOperating modes
- Speed-stage switching
Manual functions
- Setting the speed stages: 3 speed stages (2 speed stages for 1~ pumps with P2 350 W)
Automatic functions
- Internal protection against non-approved high winding temperatures (only for pumps for which P2 180 W)
Signal and display functions
- Thermal winding contact (WSK, potential-free NC contact) only for pumps for which P2 180 W) for full motor protection in all speed levels with optional tripping unit SK 602N/SK 622N
- Direction of rotation control light (only for 3~pumps )
- Display of selected speed stage
Dual pump management (twin-head pump or 2 x single pumps)
- Main/standby operation or parallel operation (for automatic fault-actuated switchover/time-dependent pump cycling, a corresponding switchgear must be provided on-site)
Equipment
- For flange-end pumps: Flange versions
- Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
- Standard version for DN 80/DN 100 pumps: PN 6 flange (engineered for PN 16 according to EN 1092-2) for PN 6 counter flange
- Cable inlet possible from both sides (only for 1~pumps and 3~pumps with P2180 W)
- Thermal insulation as standard for heating applications
Example:
TOPS 40/10
TOP-S
Standard pump (screw-end pump or flange-end pump)
40/
Nominal connection diameter
10
Nominal delivery head [m] at Q = 0 m3/ h
In stock
Free Standard Delivery
-
WIL-4148418
Wilo - Economy MHIE 406N-2G EPDM 1.4301 Centrifugal Pump - 400V - Three Phase - ObsoleteOrder the Wilo - Economy MHIIE 406N-2G EPDM 1.4301 Centrifugal Pump from Pumpify and recieve free standard delivery.
Need techinical advice on the product? Give our technical team a call on: 0800 008 6405
Multistage, non-self-priming, horizontal high-pressure Centrifugal Pump in block design with horizontal suction port and vertical pressure port and built-in, air-cooled frequency converter. The integrated frequency converter enables variable speed, pressure and PID control.
Speed control
"Speed control" : Manually with green button or via external signals, "Differential pressure, constant" : Pressure control with pressure sensor, setpoint adjustment via green button or via external signals, and "PID control": other constant control variables (temperature, volume flow, pressure....) with sensor, setpoint adjustment with green button, by means of external signals.
The electronic module delivers various protective functions. They include overload protection, the detection of low water, mains undervoltage or overvoltage, high ambient temperature, missing phases, blocked pumps and short-circuits. Error messages are issued on the display.
Short-circuit-proof +24 V voltage output with max. contact strength of 30 mA is present on the electronic module. The module has potential-free contacts for SSM, red and green LED for ON/OFF signal.
Out Of StockFree Standard Delivery
-
WIL-4148424
Wilo - Economy MHIE 803N-2G EPDM 1.4301 Multistage Centrifugal Pump - 400V - Three Phase2.2KW three phase multistage Centrifugal Pump, with 1 1/4" threaded connections.
Need techinical advice before purchasing this pump? Contact our technical suppport team on: 0800 008 6405
In stock
Free Standard Delivery
-
WIL-2121218
Wilo - Veroline IPL 65/115-1,5/2 IE3 Centrifugal Pump - 1.5 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2121201
Wilo - Veroline IPL 40/120-1.5/2 Centrifugal Pump - 1.50 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2089585
Wilo - Veroline IPL 40/115-0.55/2 -IE3 Centrifugal Pump - 0.55 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2152442
Wilo - Veroline IPL 50/95-0,55/2 Centrifugal Pump - 0.55 kWSingle-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
In stock
Free Standard Delivery
-
WIL-2121194
Wilo - Veroline IPL 100/165-2,2/4 Centrifugal Pump - 2.20 kWThe Veroline IPL Centrifugal Pumps are a range of single-stage, low-pressure Centrifugal Pump in in line design with mechanical seal, flange connection with pressure measuring connection R 1/8 and motor with one-piece shaft.
Purchase from Pumpify and recieve free standard delivery.
Type key
Your advantagesExample
IPL 40/160-4/2
IPL
in line pump
40
Nominal diameter DN of the pipe connection
160
Nominal impeller diameter
4
Rated motor power P2 in kW
2
Number of poles
High standard of corrosion protection thanks to cataphoretic coating, Standard condensate drainage holes in the motor housings and lanterns, Series Product detail: motor with one-piece shaft, Version N: Standard motor V1 with Stainless Steel plug shaft, and Bidirectional, force-flushed mechanical seal.
Tech InfoPermissible temperature range -20 °C to +120 °C, Mains connection 3~400 V, 50 Hz (others on request), Protection class IP 55, Nominal diameter Rp 1 to DN 100, and Max. operating pressure 10 bar. (special version: 16 bar.).
Materials- Pump housing and lantern: EN-GJL-250
- Impeller: PPO fibreglass-reinforced EN-GJL-200 (depending on pump type)
- Shaft: 1.4021
- Mechanical seal: AQEGG; other mechanical seals on request
In stock
Free Standard Delivery