Wilo

(12151 products)

2 products in this section | View All
Filters Products
Filter Products
  1. Electrical supply
    380V
  2. Electrical supply
    240V
Filters Products
Cable length
  1. 1.5m 1 item
Max Head
  1. 0 - 10m 1 item
Port To Port
  1. 250mm 4 items
  2. 260mm 20 items
  3. 280mm 4 items
  4. 320mm 16 items
  5. 340mm 29 items
  6. 360mm 12 items
Price
Pump Material
Pump Type Filter
  1. Centrifugal Pump 42 items
  2. Circulating Pump 43 items
  3. Sewage Pump 1 item
Bars
  1. 1.5 bar 1 item
  2. 10 bar 81 items
  3. 16 bar 1 item
View as Grid List

86 Items

Page
per page
Filter Products
Set Descending Direction
  1. Wilo Drainlift M2-8 RV Sewage Lifting Unit - Single Phase

    2531400

    Wilo - Drainlift M2-8 RV Sewage Lifting Unit - 230V - Single Phase

    Ready-for-connection, fully submersible and automatic sewage lifting unit as a double pump system with automatic duty cycling, standby and peak-load operation. Dry motor in single-phase version with Stainless Steel housing and thermal motor monitoring.

    Gas-tight and water-tight collection reservoir made from plastic with tapering collection chamber for dependable operation without any build-up of deposits, freely selectable inlets and a level control device with a rod float switch.

    Central pressure connection with integrated Y-pipe, non-return valve, and lifting device.

    Microprocessor-controlled switchgear with:

    - LEDs for displaying operating status and error messages
    - Adjustable run-on time
    - Integrated and mains-independent alarm
    - 1x potential-free contact for connection of a collective fault signal (SSM)

    Scope of delivery:

    - Sewage lifting unit ready for connection with switchgear and plug
    - 1x inlet seal DN 100
    - 1x hole saw for inlet DN 100
    - 1x lip seal for connection of diaphragm hand pump or inlet connection Ø 50 mm
    - 1x collar for ventilation connection DN 70
    - 1x flange connector DN 80/100 with flat gasket, flexible hose section and fixing material for pressure connection DN 100
    - 9 V rechargeable battery
    - 11x sound absorption strips for sound insulation Installation manual
    - Fixation material

    Operating Data:

    Fluid to be pumped : Water 100 %
    Fluid temperature : 20 °C
    Delivery head at Q=0 : 8,50 m

    Permitted field of application:

    Max. ambient temperature : 40 °C
    Min. fluid temperature : 3 °C
    Max. fluid temperature : 40 °C
    Max. fluid temperature, for short periods up to 3 min : 60 °C
    Maximum operating pressure : 1,5 bar.
    Max. permissible pressure in the pressure pipe : 150 kPa Unit
    Gross volume : 115 l
    Max. switching volume : 40 l
    Inlet connection : DN 40/DN 100/DN 150
    Pressure connection : DN 80
    Venting : DN 70
    Operating mode per pump : S3-15%, 80 sec
    Min. level ON : 180 mm
    Dimensions : 810 x 505 x 780 mm
    Diagonal dimension : 970 mm
    Weight approx. : 91 kg

    Motor

    Mains connection : 1~230V/50 Hz
    Power consumption P1 : 1,3 kW
    Rated speed : 2900 1/min
    Rated current : 5,8 A


    £9,610.80 RRP £5,958.70 £4,965.58
    In Stock In stock
    Delivery Icon Free Standard Delivery
  2. Wilo VeroTwin DP-E32/105-0,75/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158937

    Wilo - VeroTwin DP-E32/105-0,75/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £8,736.00 RRP £5,678.40 £4,732.00
    In Stock In stock
    Delivery Icon Free Standard Delivery
  3. Wilo VeroTwin DP-E32/105-0,75/2-R1 IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2159000

    Wilo - VeroTwin DP-E32/105-0,75/2-R1 IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £7,980.00 RRP £5,187.00 £4,322.50
    In Stock 6 week lead time
    Delivery Icon Free Standard Delivery
  4. Wilo VeroTwin DP-E32/125-1,1/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158938

    Wilo - VeroTwin DP-E32/125-1,1/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £8,806.80 RRP £5,724.42 £4,770.35
    In Stock In stock
    Delivery Icon Free Standard Delivery
  5. Wilo VeroTwin DP-E32/125-1,1/2-R1 IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2159001

    Wilo - VeroTwin DP-E32/125-1,1/2-R1 IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £8,052.00 RRP £5,233.80 £4,361.50
    In Stock 6 week lead time
    Delivery Icon Free Standard Delivery
  6. Wilo VeroTwin DP-E32/135-1,1/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158939

    Wilo - VeroTwin DP-E32/135-1,1/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £8,976.00 RRP £5,834.40 £4,862.00
    In Stock In stock
    Delivery Icon Free Standard Delivery
  7. Wilo VeroTwin DP-E32/135-1,1/2-R1 IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2159002

    Wilo - VeroTwin DP-E32/135-1,1/2-R1 IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £8,220.00 RRP £5,343.00 £4,452.50
    In Stock 6 week lead time
    Delivery Icon Free Standard Delivery
  8. Wilo VeroTwin DP-E32/135-1,5/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158940

    Wilo - VeroTwin DP-E32/135-1,5/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £10,443.60 RRP £6,788.34 £5,656.95
    In Stock In stock
    Delivery Icon Free Standard Delivery
  9. Wilo VeroTwin DP-E32/135-1,5/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2159003

    Wilo - VeroTwin DP-E32/135-1,5/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £9,687.60 RRP £6,296.94 £5,247.45
    In Stock In stock
    Delivery Icon Free Standard Delivery
  10. Wilo VeroTwin DP-E32/95-0,55/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158936

    Wilo - VeroTwin DP-E32/95-0,55/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £8,492.40 RRP £5,520.06 £4,600.05
    In Stock In stock
    Delivery Icon Free Standard Delivery
  11. Wilo VeroTwin DP-E32/95-0,55/2-R1 IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158999

    Wilo - VeroTwin DP-E32/95-0,55/2-R1 IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 260mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £7,736.40 RRP £5,028.66 £4,190.55
    In Stock 6 week lead time
    Delivery Icon Free Standard Delivery
  12. Wilo VeroTwin DP-E40/115-0,55/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158941

    Wilo - VeroTwin DP-E40/115-0,55/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 250mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £8,774.40 RRP £5,703.36 £4,752.80
    In Stock In stock
    Delivery Icon Free Standard Delivery
  13. Wilo VeroTwin DP-E40/115-0,55/2-R1 IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2159004

    Wilo - VeroTwin DP-E40/115-0,55/2-R1 IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 250mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £8,020.80 RRP £5,213.52 £4,344.60
    In Stock 6 week lead time
    Delivery Icon Free Standard Delivery
  14. Wilo VeroTwin DP-E40/120-1,5/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158942

    Wilo - VeroTwin DP-E40/120-1,5/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 320mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £12,049.20 RRP £7,831.98 £6,526.65
    In Stock In stock
    Delivery Icon Free Standard Delivery
  15. Wilo VeroTwin DP-E40/120-1,5/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2159005

    Wilo - VeroTwin DP-E40/120-1,5/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 320mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £11,294.40 RRP £7,341.36 £6,117.80
    In Stock 6 week lead time
    Delivery Icon Free Standard Delivery
  16. Wilo VeroTwin DP-E40/130-2,2/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158943

    Wilo - VeroTwin DP-E40/130-2,2/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 320mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £13,215.60 RRP £8,590.14 £7,158.45
    In Stock In stock
    Delivery Icon Free Standard Delivery
View as Grid List

86 Items

Page
per page
Filter Products
Set Descending Direction