2120655
Wilo - Yonos Maxo 65/0,5-16 PN6/10 Circulator Pump - 230V - Single Phase - 817 Ltr/min. - 340mmHigh efficiency pump Wilo-Yonos MAXO
is an electronically controlled,
Glandless circulator, synchronous motor according to ECM technology and integrated power control for continuous differential pressure control. can be utilised for all heating, ventilation and air-conditioning applications.
Standard-equipped with:
In stock
Free Standard Delivery
-
2164656
Wilo - Stratos Maxo-D 50/0,5-16 PN6/10 Glandless Twin Head Circulator Pump - 230V - Single Phase - 10 Bar. - 340mmPremium smart-pump Wilo-Stratos MAXO-D
High-efficiency in-line glandless twin-head pump with EC motor and electronic power adjustment. can be utilised for chilled water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between ⤠0.17 and ⤠0.19 depending on pump type.
Control modes:
In stock
Free Standard Delivery
-
2186300
Wilo - Stratos Maxo-D 50/0,5-16 PN16 Glandless Twin Head Circulator Pump - 230V - Single Phase - 16 Bar. - 340mmPremium smart-pump Wilo-Stratos MAXO-D
High-efficiency in-line glandless twin-head pump with EC motor and electronic power adjustment. can be utilised for chilled water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between ⤠0.17 and ⤠0.19 depending on pump type.
Control modes:
In stock
Free Standard Delivery
-
99221407
Grundfos - MAGNA1 80-80F (360) Variable Speed Circulator Pump - 240V - Single Phase - 834 Ltr/min. - Cast IronMAGNA1 80-80 F
The Grundfos MAGNA1 circulator Pump is the straightforward option for a job well done. With its elevated energy performance, the product complies with the EuP 2015 regulations, ensuring substantial savings on electricity. With its intuitive, user-friendly interface and maintenance-free design, MAGNA1 is the ideal circulator Pump for basic output needs in applications where basic installation management and monitoring are desired.
With this range of circulator Pumps, everything from setup to basic management and monitoring are made simple. The Pump is maintenance-free due to the canned-rotor type design. MAGNA1 provides the possibility of monitoring the Pump via the fault relay output. The digital start and stop input remotely management the Pump. The Pump communicates wirelessly with the Grundfos GO Remote app. MAGNA1 can work as the main Pump in both heating and cooling applications,
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Domestic heating, Industrial heating,
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 6 Bar.
- Temperature liquid range: -10 .. 110 °C.
- Approvals include CE,VDE,EAC,MOROCCO,UKCA,TSE,RCM,UkrSEPRO
In stock
Free Standard Delivery
-
96110246
Grundfos - TPED 80-340/4 A-F-A-BQQE-NX3 Twin Head In-Line Circulator Pump - 415V - Three Phase - 1834 Ltr/min. - Cast IronTPED 80-340/4 A-F-A-BQQE-NW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99272260
Grundfos - TPE3 50-200 S-A-F-A-BQQE-HAC Variable Speed In-Line Circulator Pump - 240V - Single Phase - 834 Ltr/min. - Cast IronTPE3 50-200 S-A-F-A-BQQE-HYC
Single-stage, close-coupled, volute Pump with in-line suction and discharge ports of identical diameter. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The Pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The Pump is equipped with a fan-cooled asynchronous motor. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
In stock
Free Standard Delivery
-
98437896
Grundfos - TPE2 50-200 N-A-F-A-BQQE-HDC Variable Speed In-Line Circulator Pump - 415V - Three Phase - 834 Ltr/min. - Cast IronTPE2 50-200 N-A-F-A-BQQE-HYC
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98416835
Grundfos - TPE3 65-120 S-A-F-I-BQQE-FAB Variable Speed In-Line Circulator Pump - 240V - Single Phase - 834 Ltr/min. - Stainless SteelTPE3 65-120 S-A-F-I-BQQE-FWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
98416722
Grundfos - TPE3 50-200 S-A-F-I-BQQE-HDC Variable Speed In-Line Circulator Pump - 415V - Three Phase - 834 Ltr/min. - Stainless SteelTPE3 50-200 S-A-F-I-BQQE-HYC
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
99114604
Grundfos - TPED 40-530/2 A-F-A-BQQE-MDB Twin Head In-Line Circulator Pump - 415V - Three Phase - 817 Ltr/min. - Cast IronTPED 40-530/2 A-F-A-BQQE-MWB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98438142
Grundfos - TPE2 D 50-240 N-A-F-A-BQQE-IDC Twin Head In-Line Circulator Pump - 415V - Three Phase - 834 Ltr/min. - Cast IronTPE2 D 50-240 N-A-F-A-BQQE-IYC
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98438354
Grundfos - TPE2 50-200 N-A-F-A-BQQE-HAC Variable Speed In-Line Circulator Pump - 240V - Single Phase - 834 Ltr/min. - Cast IronTPE2 50-200 N-A-F-A-BQQE-HYC
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99113933
Grundfos - TPE 40-530/2 A-F-A-BQQE-MDB Variable Speed In-Line Circulator Pump - 415V - Three Phase - 817 Ltr/min. - Cast IronTPE 40-530/2 A-F-A-BQQE-MWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99272218
Grundfos - TPE3 50-200 S-A-F-A-BQQE-HDC Variable Speed In-Line Circulator Pump - 415V - Three Phase - 834 Ltr/min. - Cast IronTPE3 50-200 S-A-F-A-BQQE-HYC
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
99272557
Grundfos - TPE3 D 50-240 S-A-F-A-BQQE-IDC Twin Head In-Line Circulator Pump - 415V - Three Phase - 834 Ltr/min. - Cast IronTPE3 D 50-240 S-A-F-A-BQQE-IYC
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
In stock
Free Standard Delivery
-
99132809
Grundfos - TPED 40-530/2 S-A-F-A-BQQE-MDB Twin Head In-Line Circulator Pump - 415V - Three Phase - 817 Ltr/min. - Cast IronTPED 40-530/2 S-A-F-A-BQQE-MWB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
Circulating Pumps
Circulating pumps move slurries, liquids, and gases through a closed system, keeping heating, cooling, and hot water circuits flowing as they should. They are most commonly used in domestic and commercial heating systems to maintain a steady supply of hot water, but they also play a key role in underfloor heating, radiator circuits, and chilled water applications.
By keeping water moving continuously, circulating pumps help balance temperatures, reduce energy waste, and ensure that taps, showers, and heating systems respond instantly when needed. Hot water circulating pumps are particularly useful in larger properties or commercial setups, where waiting for water to heat can lead to unnecessary water and energy use.
At Pumpify, our range includes circulating pumps suitable for everything from simple domestic setups to more complex commercial systems. Designed for easy installation, straightforward maintenance, and long-term performance, these pumps ensure your heating and hot water systems operate smoothly, reliably, and cost-effectively.