99114632
Grundfos - TPED 100-110/4 A-F-A-BQQE-JDA Twin Head Centrifugal Pump - 415V - Three Phase - 2185 Ltr/min. - Cast IronTPED 100-110/4 A-F-A-BQQE-JWA
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99114633
Grundfos - TPED 100-130/4 A-F-A-BQQE-KDA Twin Head Centrifugal Pump - 415V - Three Phase - 1617 Ltr/min. - Cast IronTPED 100-130/4 A-F-A-BQQE-KWA
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99132862
Grundfos - TPED 100-170/4 S-A-F-A-BQQE-LDA Twin Head Centrifugal Pump - 415V - Three Phase - 1784 Ltr/min. - Cast IronTPED 100-170/4 S-A-F-A-BQQE-LWA
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
99114637
Grundfos - TPED 125-130/4 A-F-A-BQQE-LDA Twin Head Centrifugal Pump - 415V - Three Phase - 2835 Ltr/min. - Cast IronTPED 125-130/4 A-F-A-BQQE-LWA
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99134474
Grundfos - TPED 40-270/2 S-A-F-A-BQQE-HAB Twin Head In-Line Circulator Pump - 240V - Single Phase - 300 Ltr/min.TPED 40-270/2 S-A-F-A-BQQE-HWB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
96945815
Grundfos - TPED 100-330/4 S-A-F-A-BQQE-OX3 Twin Head Centrifugal Pump - 415V - Three Phase - 2935 Ltr/min. - Cast IronTPED 100-330/4 S-A-F-A-BQQE-OW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
99114634
Grundfos - TPED 100-170/4 A-F-A-BQQE-LDA Twin Head Centrifugal Pump - 415V - Three Phase - 1784 Ltr/min. - Cast IronTPED 100-170/4 A-F-A-BQQE-LWA
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99114829
Grundfos - TPED 32-230/2 A-F-A-BQQE-FDB Twin Head In-Line Circulator Pump - 415V - Three Phase - 166 Ltr/min.TPED 32-230/2 A-F-A-BQQE-FWB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
96384280
Grundfos - TPD 50-190/2 A-F-A-BQQE-HX1 In-Line Twin Head Circulator Pump - 240V - Single Phase - 417 Ltr/min. - Cast IronTPD 50-190/2 A-F-A-BQQE-HW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
96384250
Grundfos - TPD 50-90/4 A-F-A-BQQE-EX3 In-Line Twin Head Circulator Pump - 240V - Single Phase - 333 Ltr/min. - Cast IronTPD 50-90/4 A-F-A-BQQE-EW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
96087153
Grundfos - TPD 50-90/4 A-F-A-BQQE-EX3 In-Line Twin Head Circulator Pump - 415V - Three Phase - 333 Ltr/min. - Cast IronTPD 50-90/4 A-F-A-BQQE-EW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
96086757
Grundfos - TPD 32-80/4 A-F-A-BQQE-CX3 In-Line Twin Head Circulator Pump - 415V - Three Phase - 150 Ltr/min. - Cast IronTPD 32-80/4 A-F-A-BQQE-CW3
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98957963
Grundfos - TPD 40-120/2 A-F-A-BQQE-DX1 In-Line Twin Head Circulator Pump - 240V - Single Phase - 291 Ltr/min.TPD 40-120/2 A-F-A-BQQE-DW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
96110024
Grundfos - TPD 150-110/6 A-F-A-BQQE-LX5 In-Line Twin Head Circulator Pump - 415V - Three Phase - 3619 Ltr/min. - Cast IronTPD 150-110/6 A-F-A-BQQE-LW5
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
96086954
Grundfos - TPD 40-300/2 A-F-A-BQQE-JX1 In-Line Twin Head Circulator Pump - 415V - Three Phase - 450 Ltr/min. - Cast IronTPD 40-300/2 A-F-A-BQQE-JW1
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
96086759
Grundfos - TPD 32-120/4 A-F-A-BQQE-EX3 In-Line Twin Head Circulator Pump - 415V - Three Phase - 216 Ltr/min.Grundfos TPD pumps are single-stage, close-coupled in-line centrifugal twin-head pumps with mechanical shaft seal and primally for applications such as heating/cooling/district energy. The pumps are fitted with fixed speed motors.
In stock
Free Standard Delivery
Heating Circulators
Heating circulator pumps keep hot water moving through radiators, baseboards, and underfloor heating systems. They ensure your heating system delivers warmth quickly, reduces waiting times for hot water, and keeps energy use under control.
Whether used individually or in combination, circulator pumps can serve multiple zones, giving precise control over each area of your property. In multi-zone systems, one circulator can serve all areas using control valves for each section, or you can fit a dedicated pump to each zone for precise, independent flow.
Modern circulators save significant power while maintaining consistent flow. Pumpify offers a range of trusted models from big name brands that are built for durability, smooth operation, and long-lasting performance, helping you get the most out of your heating system.