-
99113939
Grundfos - TPE 50-420/2 A-F-A-BQQE-MDB Variable Speed In-Line Circulator Pump - 415V - Three Phase - 950 Ltr/min. - Cast IronTPE 50-420/2 A-F-A-BQQE-MWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98122047
Grundfos - TP 40-30/4 A-F-Z-BQQE-AX3 Single Head In-Line Circulator Pump - 415V - Three Phase - 208 Ltr/min. - Stainless SteelTP 40-30/4 A-F-Z-BQQE-AW3
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled asynchronous motor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
99113926
Grundfos - TPE 32-380/2 A-F-A-BQQE-JDB Variable Speed In-Line Circulator Pump - 415V - Three Phase - 383 Ltr/min. - Cast IronTPE 32-380/2 A-F-A-BQQE-JWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98437896
Grundfos - TPE2 50-200 N-A-F-A-BQQE-HDC Variable Speed In-Line Circulator Pump - 415V - Three Phase - 834 Ltr/min. - Cast IronTPE2 50-200 N-A-F-A-BQQE-HYC
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98438567
Grundfos - TPE2 D 50-80 N-A-F-A-BQQE-DAB Twin Head In-Line Circulator Pump - 240V - Single Phase - 467 Ltr/min. - Cast IronTPE2 D 50-80 N-A-F-A-BQQE-DYB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98743793
Grundfos - TP 125-80/6 A-F-A-BQQE-JX5 Single Head In-Line Circulator Pump - 415V - Three Phase - 2335 Ltr/min.Grundfos TP pumps are single-stage, close-coupled in-line centrifugal pumps with mechanical shaft seal and primely for applications such as heating/cooling/district energy. The pumps are fitted with fixed speed motors.
In stock
Free Standard Delivery
-
98437899
Grundfos - TPE2 65-80-N A F A BQQE Single Head In-Line Circulator Pump - 415V - Three Phase - 650 Ltr/min.Grundfos TPE Series 1000, TPE2 pumps are single-stage, close-coupled in-line centrifugal pumps with mechanical shaft seal and primely for applications such as heating/cooling/district energy. The pumps are fitted with frequency controlled motors.
In stock
Free Standard Delivery
-
98742662
Grundfos - TPD 125-130/6 A-F-A-BQQE-LX5 Twin Head Circulator Pump - 415V - Three Phase - 2401 Ltr/min. - Cast IronTPD 125-130/6 A-F-A-BQQE-LW5
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled asynchronous motor of indentical size.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98438572
Grundfos - TPE2 D 65-60 N-A-F-A-BQQE-DAB Twin Head In-Line Circulator Pump - 240V - Single Phase - 533 Ltr/min. - Cast IronTPE2 D 65-60 N-A-F-A-BQQE-DYB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98438573
Grundfos - TPE2 D 65-80 N-A-F-A-BQQE-EAB Twin Head In-Line Circulator Pump - 240V - Single Phase - 650 Ltr/min. - Cast IronTPE2 D 65-80 N-A-F-A-BQQE-EYB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99114726
Grundfos - TPE 125-110/4 S-A-F-A-BQQE-KDA Variable Speed In-Line Circulator Pump - 415V - Three Phase - 2635 Ltr/min. - Cast IronTPE 125-110/4 S-A-F-A-BQQE-KWA
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
99272253
Grundfos - TPE3 40-200-S A F A BQQE Single Head In-Line Circulator Pump - 240V - Single Phase - 533 Ltr/min. - Cast IronTPE3 40-200 S-A-F-A-BQQE-GYC
Single-stage, close-coupled, volute Pump with in-line suction and discharge ports of identical diameter. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The Pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The Pump is equipped with a fan-cooled asynchronous motor. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
In stock
Free Standard Delivery
-
99272212
Grundfos - TPE3 40-240 S-A-F-A-BQQE-HDC Variable Speed In-Line Circulator Pump - 415V - Three Phase - 600 Ltr/min. - Cast IronTPE3 40-240 S-A-F-A-BQQE-HYC
Single-stage, close-coupled, volute Pump with in-line suction and discharge ports of identical diameter. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The Pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The Pump is equipped with a fan-cooled asynchronous motor. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
In stock
Free Standard Delivery
-
99113929
Grundfos - TPE 40-300/2 A-F-A-BQQE-JDB Single Head In-Line Circulator Pump - 415V - Three Phase - 533 Ltr/min. - Cast IronTPE 40-300/2 A-F-A-BQQE-JWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98438560
Grundfos - TPE2 D 40-80 N-A-F-A-BQQE-CAB Twin Head In-Line Circulator Pump - 240V - Single Phase - 333 Ltr/min.Grundfos TPE Series 1000, TPE2 pumps are single-stage, close-coupled in-line centrifugal pumps with mechanical shaft seal and primely for applications such as heating/cooling/district energy. The pumps are fitted with frequency controlled motors.
In stock
Free Standard Delivery
-
98505215
Grundfos - TP 40-90/4 A-F-Z-BQQE-CX3 Single Head In-Line Circulator Pump - 415V - Three Phase - 150 Ltr/min. - Stainless SteelTP 40-90/4 A-F-Z-BQQE-CW3
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled asynchronous motor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
Heating Circulators
Heating circulator pumps keep hot water moving through radiators, baseboards, and underfloor heating systems. They ensure your heating system delivers warmth quickly, reduces waiting times for hot water, and keeps energy use under control.
Whether used individually or in combination, circulator pumps can serve multiple zones, giving precise control over each area of your property. In multi-zone systems, one circulator can serve all areas using control valves for each section, or you can fit a dedicated pump to each zone for precise, independent flow.
Modern circulators save significant power while maintaining consistent flow. Pumpify offers a range of trusted models from big name brands that are built for durability, smooth operation, and long-lasting performance, helping you get the most out of your heating system.















