2217978
Wilo - Stratos MAXO-D 50/0,5-6 PN6/10-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 10 Bar. - 240mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217979
Wilo - Stratos MAXO-D 50/0,5-8 PN6/10-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 10 Bar. - 240mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217980
Wilo - Stratos MAXO-D 50/0,5-9 PN6/10-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 10 Bar. - 280mmPremium smart-pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217981
Wilo - Stratos MAXO-D 50/0,5-12 PN6/10-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 10 Bar. - 280mmPremium smart-pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head central heating pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217982
Wilo - Stratos MAXO-D 50/0,5-16 PN6/10-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 10 Bar. - 340mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217983
Wilo - Stratos MAXO-D 65/0,5-6 PN6/10-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 10 Bar. - 280mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217984
Wilo - Stratos MAXO-D 65/0,5-12 PN6/10-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 340mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217985
Wilo - Stratos MAXO-D 65/0,5-16 PN6/10-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 340mmPremium smar central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217986
Wilo - Stratos MAXO-D 80/0,5-6 PN6-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 10 Bar. - 360mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217987
Wilo - Stratos MAXO-D 80/0,5-6 PN10-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 10 Bar. - 360mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217988
Wilo - Stratos MAXO-D 80/0,5-12 PN6-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 6 Bar. - 360mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217989
Wilo - Stratos MAXO-D 80/0,5-12 PN10-R7 Glandless Twin Head Circulator Pump- 230V - Single Phase - 10 Bar. - 360mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217990
Wilo - Stratos MAXO-D 80/0,5-16 PN6-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 6 Bar. - 360mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2217991
Wilo - Stratos MAXO-D 80/0,5-16 PN10-R7 Glandless Twin Head Circulator Pump - 230V - Single Phase - 360mmPremium smart central heating pump Wilo-Stratos MAXO-D-R7
High-efficiency in line glandless twin-head pump with EC motor and electronic power adjustment. Can be utilised for Cold water, heating water and water/glycol mixtures. Energy efficiency index (EEI) between 𢧠0.17 and 𢧠0.19 depending on pump type.
Control modes:
Permanent, automatic power adjustment to system requirements without setpoint specification Wilo - Dynamic Adapt plus (factory setting). Up to 20% energy savings compared to dp-v control mode., Constant temperature (T-const.), Constant differential temperature (dT-const.), Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple pumps (Multi-Flow Adaptation)., Constant volume flow (Q-const.), Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator), Constant differential pressure (dp-c), Variable differential pressure (dp-v) with the option to set the nominal duty point, Constant speed (n-const.), and User-defined PID control.
Product Functions:
Heat quantity measurement, Cooling quantity measurement, Pump automatically deactivates when no flow is detected (No-Flow Stop), Switchover between heating and cooling mode (automatic, external or manual) (automatic, possible with Stratos MAXO temperature sensor), Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.), Operating modes of twin-head pumps: Efficiency-optimised parallel operation for dp-c and dp-v, main and standby operation, Ability to save and restore configured pump settings (3 restoration points), Fault and warning messages shown in plain text with advice on resolving the issue, Pump venting function for automatic venting of the rotor chamber, Automatic setback operation (possible with Stratos MAXO temperature sensor), Automatic deblocking function and integrated full motor protection, and Dry-running detection.
Display:
- Control mode
- Setpoint
- Volume flow
- Temperature (possible with Stratos MAXO temperature sensor)
- Power consumption
- Electric consumption
- Active influences (e.g. STOP, No-Flow Stop)
Version:
- 2 configurable analogue inputs: 0š10 V, 2š10 V, 0š20 mA, 4š20 mA and commercially available PT1000; +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation BA (optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen)
- Wilo - Net as a Wilo - system bus for communication between Wilo - products, e.g. Multi-Flow Adaptation; twin-head pump operation and Wilo-Smart Gateway
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Graphic colour display (4.3 inches) with one-button manual operation
- Use the Wilo-Assistant app to read and set operating data and šamong other thingsš set up a commissioning protocol through the Bluetooth interface (no further accessories required)
- Integrated dual pump management (twin-head pumps are prewired) when using 2 single pumps as twin-head pump unit (connection via Wilo - Net)
- Cable break detection when using an analogue signal (in connection with 2š10 V or 4š20 mA)
- Outdoor Installation manual with weather protection possible in accordance with the Installation manual and operating instructions
- Pre-set date and time
Scope of delivery
- Pump
- 2x optimised Wilo-Connector, appropriate for all sizes
- 4x threaded cable gland, M16 x 1.5
- 2x gaskets
- Concise Installation manual and operating instructions
Optional accessories:
- CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen
- PT 1000 (B) pipe contact sensor (for domestic Hot water)
- PT 1000 (AA) sensor for Installation manual in immersion well
- Differential pressure sensor
- Smart Gateway
- Stratos MAXO temperature sensor (can be retrofitted for recording and displaying the fluid temperature and using the temperature-controlled control modes T-const., dT-const.)
In stock
Free Standard Delivery
-
2088310
Wilo - CronoLine IL40/220-1,5/4 - IE2 Single Head Inline Pump - 400V - Single PhaseFor pumping Cold and Hot water (according to VDI 2035) without abrasive substances in heating water, Cold water and cooling water systems
Features & Advantages:
Long motor life guaranteed by standard ondensate drainage holes in the motor housing, Corrosion protection through cataphoretic coating, and Feet with threaded holes on the pump housing make it easy to install.
In stock
Free Standard Delivery
-
98923198
Grundfos - TP 65-60/4 A-F-A-BQQE-EX3 Variable Speed Inline Circulator Pump - 400V - Three Phase - 633 Ltr/min.TP 65-60/4 A-F-A-BQQE-EW3
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
Heating Circulators
Heating circulator pumps keep hot water moving through radiators, baseboards, and underfloor heating systems. They ensure your heating system delivers warmth quickly, reduces waiting times for hot water, and keeps energy use under control.
Whether used individually or in combination, circulator pumps can serve multiple zones, giving precise control over each area of your property. In multi-zone systems, one circulator can serve all areas using control valves for each section, or you can fit a dedicated pump to each zone for precise, independent flow.
Modern circulators save significant power while maintaining consistent flow. Pumpify offers a range of trusted models from big name brands that are built for durability, smooth operation, and long-lasting performance, helping you get the most out of your heating system.