Wilo

(12151 products)

0 products in this section | View All
Filters Products
Filters Products
Next Day Delivery
Cable length
  1. 1.5m 1 item
Max Head
  1. 0 - 10m 192 items
  2. 11 - 20m 117 items
  3. 21 - 30m 13 items
  4. 31 - 40m 12 items
  5. 41 - 50m 2 items
  6. 51 - 60m 2 items
Port To Port
  1. 130mm 11 items
  2. 138mm 1 item
  3. 140mm 1 item
  4. 150mm 6 items
  5. 180mm 92 items
  6. 220mm 41 items
  7. 240mm 13 items
  8. 250mm 34 items
  9. 260mm 28 items
  10. 280mm 38 items
  11. 320mm 23 items
  12. 340mm 84 items
  13. 360mm 74 items
  14. 430mm 3 items
  15. 440mm 2 items
  16. 500mm 3 items
  17. 800mm 1 item
Pressure Rating
Price
Pump Type Filter
  1. Central Heating Pump 3 items
  2. Centrifugal Pump 141 items
  3. Circulating Pump 247 items
  4. Circulator Pump 104 items
  5. Multistage 3 items
  6. Pressurisation Unit 2 items
  7. Replacement Pump Head 23 items
  8. Sewage Pump 1 item
  9. Spares 19 items
  10. Sump Pump 1 item
Bars
  1. 1.5 bar 1 item
  2. 6 bar 14 items
  3. 9 bar 1 item
  4. 10 bar 324 items
  5. 16 bar 90 items
View as Grid List

578 Items

per page
Filter Products
Set Descending Direction
  1. Wilo VeroTwin DP-E80/105-3/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2159018

    Wilo - VeroTwin DP-E80/105-3/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 360mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £14,134.80 RRP £9,187.62 £7,656.35
    In Stock 6 week lead time
    Delivery Icon Free Standard Delivery
  2. Wilo VeroTwin DP-E80/110-4/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158956

    Wilo - VeroTwin DP-E80/110-4/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 360mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £16,510.80 RRP £10,732.02 £8,943.35
    In Stock In stock
    Delivery Icon Free Standard Delivery
  3. Wilo VeroTwin DP-E80/110-4/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2159019

    Wilo - VeroTwin DP-E80/110-4/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 360mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £15,753.60 RRP £10,239.84 £8,533.20
    In Stock 6 week lead time
    Delivery Icon Free Standard Delivery
  4. Wilo VeroTwin DP-E80/115-2,2/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2158954

    Wilo - VeroTwin DP-E80/115-2,2/2-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 360mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £14,288.40 RRP £9,287.46 £7,739.55
    In Stock In stock
    Delivery Icon Free Standard Delivery
  5. Wilo VeroTwin DP-E80/115-2,2/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 bar

    2159017

    Wilo - VeroTwin DP-E80/115-2,2/2-R1-IE4 Centrifugal Pump - 380v - Three Phase - 10 Bar. - 360mm

    Glanded twin-head pump with in line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

    Product detail:

    Single-stage low-pressure Centrifugal Pump with one-piece shaft, Spiral housing, in line design, PN 16 flange Ä drilled according to EN 1092-2, Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor), Pump housing and motor flange with cataphoretic coating as standard, and Mechanical seal for water feed up to T=120 ∞C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 ∞C. Other mechanical seals or other fluids/temperatures on request..

    Accessories:

    Mounting brackets for fixing to the foundation, IR-Monitor, IF module PLR, IF module LON, IF module Modbus, IF module BACnet, IF module CAN, and Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1.

    Standard equipment:

    • One-button manual operation level for:
      • Pump On/Off
      • Setpoint and speed adjustment
      • Selecting the control mode: Œîp-c (constant differential pressure), Œîp-v (variable differential pressure), PID controller, n-constant (constant speed)
      • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
      • Configuration of operating parameters
      • Fault acknowledgement
    • Pump display for displaying:
      • Control mode
      • Setpoint (e.g. differential pressure or speed)
      • Error and warning messages
      • Actual values (e.g. power consumption, actual value of the sensor)
      • Operating data (e.g. operating hours, energy consumption)
      • Status data (e.g. status of SSM and SBM relay)
      • Device data (e.g. pump name)

    Additional Product Functions:

    • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0Ä10 V, 2Ä10 V, 0Ä20 mA, 4Ä20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo - IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
    • Adjustable time interval for pump cycling (in dual pump mode)
    • Integrated full motor protection
    • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
    • Access disable
    • Different operation levels: Standard / Service

    £13,533.60 RRP £8,796.84 £7,330.70
    In Stock 6 week lead time
    Delivery Icon Free Standard Delivery
  6. Wilo Yonos Pico 15/1-4-(ROW) Circulator Pump - 230v - Single Phase - 45 Ltr/min

    4215511

    Wilo - Yonos Pico 15/1-4-(ROW) Circulator Pump - 230V - Single Phase - 45 Ltr/min. - 130mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £196.80 RRP £157.44 £131.20
    In Stock In stock
    Delivery Icon Free Standard Delivery
  7. Wilo Yonos Pico 15/1-6-(ROW) Circulator Pump - 230v - Single Phase - 60 Ltr/min

    4215512

    Wilo - Yonos Pico 15/1-6-(ROW) Circulator Pump - 230V - Single Phase - 60 Ltr/min. - 130mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £199.20 RRP £159.36 £132.80
    In Stock In stock
    Delivery Icon Free Standard Delivery
  8. Wilo Yonos Pico 25/1-4-(ROW) Circulator Pump - 230v - Single Phase - 45 Ltr/min

    4215513

    Wilo - Yonos Pico 25/1-4-(ROW) Circulator Pump - 230V - Single Phase - 45 Ltr/min. - 180mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £469.20 RRP £375.36 £312.80
    In Stock In stock
    Delivery Icon Free Standard Delivery
  9. Wilo Yonos Pico 25/1-4-130-(ROW) Circulator Pump - 230v - Single Phase - 45 Ltr/min

    4215514

    Wilo - Yonos Pico 25/1-4-130-(ROW) Circulator Pump - 230V - Single Phase - 45 Ltr/min. - 130mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £652.80 RRP £522.24 £435.20
    In Stock In stock
    Delivery Icon Free Standard Delivery
  10. Wilo Yonos Pico 25/1-5-130-(ROW) Circulator Pump - 230v - Single Phase - 10 bar

    4215522

    Wilo - Yonos Pico 25/1-5-130-(ROW) Circulator Pump - 230V - Single Phase - 10 Bar. - 130mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £228.00 RRP £182.40 £152.00
    In Stock In stock
    Delivery Icon Free Standard Delivery
  11. Wilo Yonos Pico 25/1-6-(ROW) Circulator Pump - 230v - Single Phase - 60 Ltr/min

    4215515

    Wilo - Yonos Pico 25/1-6-(ROW) Circulator Pump - 230V - Single Phase - 60 Ltr/min. - 180mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £344.40 RRP £275.52 £229.60
    In Stock In stock
    Delivery Icon Free Standard Delivery
  12. Wilo Yonos Pico 25/1-6-130-(ROW) Circulator Pump - 230v - Single Phase - 60 Ltr/min

    4215516

    Wilo - Yonos Pico 25/1-6-130-(ROW) Circulator Pump - 230V - Single Phase - 60 Ltr/min. - 130mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £247.20 RRP £197.76 £164.80
    In Stock In stock
    Delivery Icon Free Standard Delivery
  13. Wilo Yonos Pico 25/1-8-(ROW) Circulator Pump - 230v - Single Phase - 73 Ltr/min

    4215517

    Wilo - Yonos Pico 25/1-8-(ROW) Circulator Pump - 230V - Single Phase - 73 Ltr/min. - 180mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £306.00 RRP £244.80 £204.00
    In Stock In stock
    Delivery Icon Free Standard Delivery
  14. Wilo Yonos Pico 25/1-8-130-(ROW) Circulator Pump - 230v - Single Phase - 73 Ltr/min

    4215518

    Wilo - Yonos Pico 25/1-8-130-(ROW) Circulator Pump - 230V - Single Phase - 73 Ltr/min. - 130mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £283.20 RRP £226.56 £188.80
    In Stock In stock
    Delivery Icon Free Standard Delivery
  15. Wilo Yonos Pico 30/1-4-(ROW) Circulator Pump - 230v - Single Phase - 45 Ltr/min

    4215519

    Wilo - Yonos Pico 30/1-4-(ROW) Circulator Pump - 230V - Single Phase - 45 Ltr/min. - 180mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £561.60 RRP £449.28 £374.40
    In Stock In stock
    Delivery Icon Free Standard Delivery
  16. Wilo - Yonos Pico 30/1-6-(ROW) Circulator Pump - 230V - Single Phase - 60 Ltr/min. - 180mm

    4215520

    Wilo - Yonos Pico 30/1-6-(ROW) Circulator Pump - 230V - Single Phase - 60 Ltr/min. - 180mm

    High-efficiency pump Wilo-Yonos PICO, electronically controlled. Maintenance-free glandless circulator with screwed connection, blocking-current proof synchronous motor according to ECM technology and built-in electronic power control for variable differential pressure control. can be utilised for all heating and air-conditioning applications. Control mode can be selected in accordance with the radiator/underfloor heating application.

    Standard-equipped with:


    £645.60 RRP £516.48 £430.40