-
98416505
Grundfos - TPE3 40-120 S-A-F-I-BQQE-DAB Variable Speed In-Line Circulator Pump - 240V - Single Phase - 375 Ltr/min. - Stainless SteelTPE3 40-120 S-A-F-I-BQQE-DYB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
96510160
Grundfos - SQE3-80 Submersible Borehole Pump - 240V - Single Phase - 50 Ltr/min.SQE 3-80
3" multi-stage, submersible pump unit designed for domestic water supply, liquid transfer in tanks, irrigation and environmental applications. The pump has "floating" impellers, each with its own tungsten carbide/ceramic bearing.The pump features soft starting and protection against dry-running, upthrust, overvoltage, undervoltage, overload and overtemperature.
The motor is a single-phase motor of the permanent magnet rotor type ensuring optimum efficiency within a wide load range. The motor is fitted with a replaceable end cover with socket.
Suitable for: Domestic ground water intake, Domestic water pressure boosting, Ground water intake
In stock
Free Standard Delivery
-
98438357
Grundfos - 98438357-120 N-A-F-A-BQQE-FAB Variable Speed In-Line Circulator Pump - 240V - Single Phase - 834 Ltr/min. - Cast IronTPE2 65-120 N-A-F-A-BQQE-FWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98514344
Grundfos - TPE 32-200/2 A-F-A-BQQE-GDB Variable Speed In-Line Circulator Pump - 415V - Three Phase - 250 Ltr/min. - Cast IronTPE 32-200/2 A-F-A-BQQE-GWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
96075909
Grundfos - SEG.40.15.2.50B Submersible Sewage Grinder Pump - 415V - Three Phase - 286 Ltr/min. - Cast IronSEG.40.15.2.50B
Grundfos SEG grinder pumps are non-self-priming, single-stage, centrifugal pumps with horizontal discharge port, specifically designed for pumping wastewater containing discharge from toilets. The pump is equipped with a grinder system that grinds destructible solids into small pieces to lead them through pipes with a relatively small diameter. SEG grinder pumps are well-suited for use in sparsely populated areas, where gravity sewage systems are not available. Examples include villages, farm areas and areas with large terrain-level differences, where a pressurised system has advantages. The pump is available for two types of installation:
The pump is made of wear-resistant materials, such as Cast Iron and Stainless Steel. These materials ensure dependable operation. The surface of the pump is smooth to prevent dirt and impurities from sticking. The corrosion-protected Stainless Steel clamp is securing the motor to the pump housing and allow the straightforward service of the pump. SmartTrim system allows straightforward adjustment of the impeller clearance to ensure maximum efficiency during the pump lifespan. The range is designed to reduce energy consumption and keep downtime costs to a minimum, while maintaining peak performance throughout the lifespan of the system.- submerged installation, free-standing
- submerged installation on auto-coupling systems
Suitable for: Commercial wastewater, Domestic wastewater, Wastewater transport, Flood control
In stock
Free Standard Delivery
-
99113938
Grundfos - TPE 50-430/2 A-F-A-BQQE-LDB Variable Speed In-Line Circulator Pump - 415V - Three Phase - 783 Ltr/min. - Cast IronTPE 50-430/2 A-F-A-BQQE-LWB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99272596
Grundfos - TPE3 D 50-150 S-A-F-A-BQQE-FAB Twin Head In-Line Circulator Pump - 240V - Single Phase - 617 Ltr/min. - Cast IronTPE3 D 50-150 S-A-F-A-BQQE-FYB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
99113696
Grundfos - TPE 65-240/4 A-F-A-BQQE-KDA Variable Speed In-Line Circulator Pump - 415V - Three Phase - 950 Ltr/min. - Cast IronTPE 65-240/4 A-F-A-BQQE-KWA
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99113655
Grundfos - TPE 125-95/4 A-F-A-BQQE-KDA Variable Speed In-Line Circulator Pump - 415V - Three Phase - 2969 Ltr/min. - Cast IronTPE 125-95/4 A-F-A-BQQE-KWA
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98438137
Grundfos - TPE2 D 50-80 N-A-F-A-BQQE-DDB Twin Head In-Line Circulator Pump - 415V - Three Phase - 467 Ltr/min. - Cast IronTPE2 D 50-80 N-A-F-A-BQQE-DYB
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
99478030
Grundfos - TPE 100-65/4 S-A-F-A-BQQE-GDA Variable Speed In-Line Circulator Pump - 415V - Three Phase - 1317 Ltr/min. - Cast IronTPE 100-65/4 S-A-F-A-BQQE-GWA
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
99272594
Grundfos - TPE3 D 50-80 S-A-F-A-BQQE-DAB Twin Head In-Line Circulator Pump - 240V - Single Phase - 483 Ltr/min. - Cast IronTPE3 D 50-80 S-A-F-A-BQQE-DYB
Single-stage, close-coupled, volute twin-head Pump with in-line suction and discharge ports of identical diameter. The twin-head Pump is engineered with two parallel power-heads. The Pump is of the top-pull-out design, i.e. the power head (motor, Pump head and impeller) can be removed for maintenance or service while the Pump housing remains in the pipework. Each power head is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. Pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is equipped with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is equipped with a fan-cooled asynchronous motor of indentical size. The motor performance is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable management of the motor speed, which again enables adaptation of the output to a given requirement. The Pump is equipped with temperature- and differential pressure sensors.
- Suitable for Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
- This product's housing material is Cast Iron
- The impeller is manufactured from Composite
- Maximum operating pressure: 10 Bar.
- Temperature liquid range: -25 .. 120 °C.
In stock
Free Standard Delivery
-
99132855
Grundfos - TPED 80-170/4 S-A-F-A-BQQE-KDA Twin Head In-Line Circulator Pump - 415V - Three Phase - 1284 Ltr/min. - Cast IronTPED 80-170/4 S-A-F-A-BQQE-KWA
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with a differential pressure sensor.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
99113702
Grundfos - TPE 100-70/4 A-F-A-BQQE-HDA Variable Speed In-Line Circulator Pump - 415V - Three Phase - 1751 Ltr/min. - Cast IronTPE 100-70/4 A-F-A-BQQE-HWA
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The pump is equipped with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 16 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery
-
98416674
Grundfos - TPE3 50-120 S-A-F-I-BQQE-EAB Variable Speed In-Line Circulator Pump - 240V - Single Phase - 633 Ltr/min. - Stainless SteelTPE3 50-120 S-A-F-I-BQQE-EYB
Single-stage, close-coupled, volute (centrifugal) pump unit with in-line suction and discharge ports of identical diameter. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). The pump is equipped with a fan-cooled, permanent-magnet synchronous motor. The pump is equipped with a fan-cooled asynchronous motor. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. The pump is equipped with temperature- and differential pressure sensors.
Suitable for: Commercial heating, Commercial air conditioning, District heating, District cooling, Industrial heating, Industrial cooling, Desalination, Drinking water treatment, Water distribution, Irrigation, Community water supply
In stock
Free Standard Delivery
-
98438140
Grundfos - TPE2 D 50-180 N-A-F-A-BQQE-GDC Twin Head In-Line Circulator Pump - 415V - Three Phase - 700 Ltr/min. - Cast IronTPE2 D 50-180 N-A-F-A-BQQE-GYC
Single-stage, close-coupled, volute twin-head pump unit with in-line suction and discharge ports of identical diameter. The twin-head pump is designed with two parallel power-heads. The pump is of the top-pull-out design, i.e. the power head (motor, pump head and impeller) can be removed for maintenance or service while the pump housing remains in the pipework. Each power head is fitted with an unbalanced rubber bellows seal. The shaft seal is according to EN 12756. All pipework connection is via PN 6/10 DIN flanges (EN 1092-2 and ISO 7005-2). Each power head is fitted with a fan-cooled, permanent-magnet synchronous motor of identical size. Each power head is fitted with a fan-cooled asynchronous motor of indentical size. The motor efficiency is classified as IE5 in accordance with IEC 60034-30-2.
Suitable for: Commercial air conditioning
In stock
Free Standard Delivery















