98975865
Grundfos - NB 100-250/242BASF2AESBQQEWW1 End Suction Pump - 400V - Three Phase - 5207 Ltr/min. - Cast IronNB 100-250/242 BASF2AESBQQEWW1
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98860204
Grundfos - NB 100-250/245BASF2AESBQQENW3 End Suction Pump - 400V - Three Phase - 2705 Ltr/min. - Cast IronNB 100-250/245 BASF2AESBQQENW3
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975864
Grundfos - NB 100-250/258BASF2AESBQQE1W1 End Suction Pump - 400V - Three Phase - 5414 Ltr/min. - Cast IronNB 100-250/258 BASF2AESBQQE1W1
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975593
Grundfos - NB 100-250/260BAF2AESBQQEKW5 End Suction Pump - 400V - Three Phase - 1854 Ltr/min. - Cast IronNB 100-250/260 BAF2AESBQQEKW5
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975592
Grundfos - NB 100-250/274BAF2AESBQQELW5 End Suction Pump - 400V - Three Phase - 1983 Ltr/min. - Cast IronNB 100-250/274 BAF2AESBQQELW5
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975863
Grundfos - NB 100-250/274BASF2AESBQQE2W1 End Suction Pump - 400V - Three Phase - 5764 Ltr/min. - Cast IronNB 100-250/274 BASF2A1ESBQQE2W1
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98856093
Grundfos - NB 100-250/274BASF2AESBQQEOW3 End Suction Pump - 400V - Three Phase - 2917 Ltr/min. - Cast IronNB 100-250/274 BASF2AESBQQEOW3
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975727
Grundfos - NB 100-315/269AASF2AESBQQE1W1 End Suction Pump - 400V - Three Phase - 4970 Ltr/min. - Cast IronNB 100-315/269 AASF2AESBQQE1W1
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98974774
Grundfos - NB 100-315/272AAF2AESBQQEKW5 End Suction Pump - 400V - Three Phase - 1644 Ltr/min. - Cast IronNB 100-315/272 AAF2AESBQQEKW5
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98567533
Grundfos - NB 100-315/279AASF2AESBQQEOW3 End Suction Pump - 400V - Three Phase - 2595 Ltr/min. - Cast IronNB 100-315/279 AASF2AESBQQEOW3
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975728
Grundfos - NB 100-315/284AASF2AESBQQE2W1 End Suction Pump - 400V - Three Phase - 5337 Ltr/min. - Cast IronNB 100-315/284 AASF2A1ESBQQE2W1
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98876482
Grundfos - NB 100-315/295AASF2AESBQQEPW3 End Suction Pump - 400V - Three Phase - 2795 Ltr/min. - Cast IronNB 100-315/295 AASF2AESBQQEPW3
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98974776
Grundfos - NB 100-315/301AAF2AESBQQELW5 End Suction Pump - 400V - Three Phase - 196 Ltr/min. - Cast IronNB 100-315/301 AAF2AESBQQELW5
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975729
Grundfos - NB 100-315/301AASF2AESBQQEYW1 End Suction Pump - 400V - Three Phase - 5769 Ltr/min. - Cast IronNB 100-315/301 AASF2AESBQQEYW1
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975636
Grundfos - NB 100-315/312AASF2AESBQQEQW3 End Suction Pump - 400V - Three Phase - 2984 Ltr/min. - Cast IronNB 100-315/312 AASF2AESBQQEQW3
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery
-
98975730
Grundfos - NB 100-315/322AASF2AESBQQEYW1 End Suction Pump - 400V - Three Phase - 6355 Ltr/min. - Cast IronNB 100-315/322 AASF2AESBQQEYW1
Non-self-priming, single-stage, centrifugal volute pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is close-coupled to a fan-cooled asynchronous motor.
Suitable for: Commercial air conditioning, Industrial heating, Irrigation
In stock
Free Standard Delivery