-
98973262
Grundfos - NK 125-200/176-154BA2F2AESBQQETW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 6420 Ltr/min. - Cast IronNK 125-200/165 BA2F2AESBQQETW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973260
Grundfos - NK 125-200/196-166BA2F2AESBQQEUW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 7017 Ltr/min. - Cast IronNK 125-200/181 BA2F2AESBQQEUW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973711
Grundfos - NK 125-200/196-180BA2F2AESBQQEMW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 4180 Ltr/min. - Cast IronNK 125-200/185 BA2F2AESBQQEMW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973270
Grundfos - NK 125-200/196-182BA2F2AESBQQEIW5 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 2540 Ltr/min. - Cast IronNK 125-200/189 BA2F2AESBQQEIW5
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973258
Grundfos - NK 125-200/205BA2F2AESBQQEVW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 8226 Ltr/min. - Cast IronNK 125-200/205 BA2F2AESBQQEVW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973269
Grundfos - NK 125-200/215BA2F2AESBQQEJW5 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 2797 Ltr/min. - Cast IronNK 125-200/215 BA2F2AESBQQEJW5
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973710
Grundfos - NK 125-200/219BA2F2AESBQQENW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 4343 Ltr/min. - Cast IronNK 125-200/219 BA2F2AESBQQENW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973257
Grundfos - NK 125-200/219BA2F2AESBQQEWW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 894 Ltr/min. - Cast IronNK 125-200/219 BA2F2AESBQQEWW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973255
Grundfos - NK 125-200/224BA2F2AESBQQE1W1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 9242 Ltr/min. - Cast IronNK 125-200/224 BA2F2AESBQQE1W1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973268
Grundfos - NK 125-200/226BA2F2AESBQQEKW5 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 3019 Ltr/min. - Cast IronNK 125-200/226 BA2F2AESBQQEKW5
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973708
Grundfos - NK 125-200/226BA2F2AESBQQEOW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 4576 Ltr/min. - Cast IronNK 125-200/226 BA2F2AESBQQEOW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972424
Grundfos - NK 125-250/216AA2F2AESBQQEJW5 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 2428 Ltr/min. - Cast IronNK 125-250/216 AA2F2AESBQQEJW5
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973519
Grundfos - NK 125-250/220AA2F2AESBQQENW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 3699 Ltr/min. - Cast IronNK 125-250/220 AA2F2AESBQQENW3
Non-self-priming, single-stage, centrifugal Pump engineered according to ISO 5199 with dimensions and rated output according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The Pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the Pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The Pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
- Suitable for Commercial heating,
- This product's housing material is Cast Iron
- The impeller is manufactured from Cast Iron
- Maximum operating pressure: 16 Bar.
- Temperature liquid range: -25 .. 120 °C.
Grundfos (est. 1945) is a Danish pump manufacturer known for high-efficiency circulators, multistage boosters, borehole and wastewater pumps, plus packaged pressure systems. The range covers HVAC circulation, domestic hot water recirculation, pressure boosting, industrial water transfer and public water management, with strong focus on energy efficiency and intelligent controls.
6 week lead time
Free Standard Delivery
-
98972898
Grundfos - NK 125-250/222AA2F2AESBQQEWW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 7948 Ltr/min. - Cast IronNK 125-250/222 AA2F2AESBQQEWW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972426
Grundfos - NK 125-250/232AA2F2AESBQQEKW5 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 2715 Ltr/min. - Cast IronNK 125-250/232 AA2F2AESBQQEKW5
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972900
Grundfos - NK 125-250/236AA2F2AESBQQE1W1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 8598 Ltr/min. - Cast IronNK 125-250/236 AA2F2AESBQQE1W1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery















