98973603
Grundfos - NK 50-160/158AA2F2AESBQQEGW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 667 Ltr/min. - Cast IronNK 50-160/158 AA2F2AESBQQEGW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973449
Grundfos - NK 50-160/167AA2F2AESBQQENW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1480 Ltr/min. - Cast IronNK 50-160/167 AA2F2AESBQQENW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98705749
Grundfos - NK 50-160/175AA2F2AESBQQEHW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 751 Ltr/min. - Cast IronNK 50-160/175 AA2F2AESBQQEHW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973606
Grundfos - NK 50-160/177AA2F2AESBQQEIW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 778 Ltr/min. - Cast IronNK 50-160/177 AA2F2AESBQQEIW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973488
Grundfos - NK 50-160/177AA2F2AESBQQEOW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1579 Ltr/min. - Cast IronNK 50-160/177 AA2F2AESBQQEOW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973608
Grundfos - NK 50-200/171AA2F2AESBQQEGW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 521 Ltr/min. - Cast IronNK 50-200/171 AA2F2AESBQQEGW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973451
Grundfos - NK 50-200/181AA2F2AESBQQENW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1180 Ltr/min. - Cast IronNK 50-200/181 AA2F2AESBQQENW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973610
Grundfos - NK 50-200/188AA2F2AESBQQEHW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 588 Ltr/min. - Cast IronNK 50-200/188 AA2F2AESBQQEHW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973492
Grundfos - NK 50-200/198AA2F2AESBQQEOW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1356 Ltr/min. - Cast IronNK 50-200/198 AA2F2AESBQQEOW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98545683
Grundfos - NK 50-200/210AA2F2AESBQQEIW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 741 Ltr/min. - Cast IronNK 50-200/210 AA2F2AESBQQEIW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98425314
Grundfos - NK 50-200/210AA2F2AESBQQEPW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1480 Ltr/min. - Cast IronNK 50-200/210 AA2F2AESBQQEPW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973612
Grundfos - NK 50-200/219AA2F2AESBQQEJW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 755 Ltr/min. - Cast IronNK 50-200/219 AA2F2AESBQQEJW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98425315
Grundfos - NK 50-200/219AA2F2AESBQQEQW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1561 Ltr/min. - Cast IronNK 50-200/219 AA2F2AESBQQEQW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973498
Grundfos - NK 50-250/205AA2F2AESBQQEOW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1178 Ltr/min. - Cast IronNK 50-250/205 AA2F2AESBQQEOW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973614
Grundfos - NK 50-250/221AA2F2AESBQQEIW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 596 Ltr/min. - Cast IronNK 50-250/221 AA2F2AESBQQEIW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973453
Grundfos - NK 50-250/222AA2F2AESBQQEPW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1221 Ltr/min. - Cast IronNK 50-250/222 AA2F2AESBQQEPW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery