98973455
Grundfos - NK 50-250/233AA2F2AESBQQEQW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1318 Ltr/min. - Cast IronNK 50-250/233 AA2F2AESBQQEQW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973616
Grundfos - NK 50-250/241AA2F2AESBQQEJW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 675 Ltr/min. - Cast IronNK 50-250/241 AA2F2AESBQQEJW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972782
Grundfos - NK 50-250/254AA2F2AESBQQERW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1521 Ltr/min. - Cast IronNK 50-250/254 AA2F2AESBQQERW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973483
Grundfos - NK 50-250/263AA2F2AESBQQEKW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 785 Ltr/min. - Cast IronNK 50-250/263 AA2F2AESBQQEKW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972784
Grundfos - NK 50-250/263AA2F2AESBQQESW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1616 Ltr/min. - Cast IronNK 50-250/263 AA2F2AESBQQESW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972786
Grundfos - NK 50-315/267AA2F2AESBQQERW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1169 Ltr/min. - Cast IronNK 50-315/267 AA2F2AESBQQERW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973485
Grundfos - NK 50-315/277AA2F2AESBQQEKW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 624 Ltr/min. - Cast IronNK 50-315/277 AA2F2AESBQQEKW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972788
Grundfos - NK 50-315/285AA2F2AESBQQESW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase -1279 Ltr/min. - Cast IronNK 50-315/285 AA2F2AESBQQESW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972790
Grundfos - NK 50-315/300AA2F2AESBQQETW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1380 Ltr/min. - Cast IronNK 50-315/300 AA2F2AESBQQETW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98074516
Grundfos - NK 50-315/303AA2F2AESBQQELW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase -713 Ltr/min. - Cast IronNK 50-315/303 AA2F2AESBQQELW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98972792
Grundfos - NK 50-315/321AA2F2AESBQQEUW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1505 Ltr/min. - Cast IronNK 50-315/321 AA2F2AESBQQEUW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98476310
Grundfos - NK 50-315/331AA2F2AESBQQEMW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 792 Ltr/min. - Cast IronNK 50-315/331 AA2F2AESBQQEMW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98973487
Grundfos - NK 50-315/344AA2F2AESBQQENW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 848 Ltr/min. - Cast IronNK 50-315/344 AA2F2AESBQQENW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98803689
Grundfos - NK 65-125/120-110AA2F2AESBQQEKW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase -1449 Ltr/min. - Cast IronNK 65-125/115 AA2F2AESBQQEKW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98876500
Grundfos - NK 65-125/121AA2F2AESBQQEEW3 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 816 Ltr/min. - Cast IronNK 65-125/120 AA2F2AESBQQEEW3
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery
-
98646989
Grundfos - NK 65-125/127AA2F2AESBQQELW1 Long Coupled Single Stage End Suction Pump - 400V - Three Phase - 1803 Ltr/min. - Cast IronNK 65-125/125 AA2F2AESBQQELW1
Non-self-priming, single-stage, centrifugal pump unit designed according to ISO 5199 with dimensions and rated performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework. The unbalanced rubber bellows seal is according to DIN EN 12756. The pump is equipped with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a common base frame.
Suitable for: Commercial heating
6 week lead time
Free Standard Delivery